3. INSTALLATION SPACE
Caution
● The installation space shown in the following examples is based on an ambient temperature under
cooling operation of 35 °C DB at the air intake of the outdoor unit.
Provide more space around the air intake than shown in the examples if the ambient temperature
exceeds 35 °C DB or if the thermal load of all of the outdoor units exceeds the capacity.
● Consider the transportation route, installation space, maintenance space, and access, and install
the unit in a location with sufficient space for the refrigerant piping.
● Observe the installation space specifications that are shown in the figures.
Provide the same space for the air intake at the rear of the outdoor unit.
If the installation is not performed according to the specifications, it could cause a short circuit and
result in a lack of operating performance.
As a result, the outdoor unit might easily be stopped by high-pressure protection.
● When there is a wall at the right side of the unit,provide a space of 100mm or more.
Air intake
Rear
Front
● Installation methods not shown in the following examples are not recommended.
Performance may drop significantly.
3-1. SINGLE OUTDOOR UNIT INSTALLATION
WHEN THE UPWARD AREA IS OPEN
Unit : mm
z
Obstacles at rear only
z
Obstacles at rear and sides only
*
100 or more
100 or more
300 or
more
80 or
more
z
Obstacles at front only
z
Obstacles at front and rear only
1000 or more
1000 or more
100 or more
WHEN AN OBSTRUCTION IS PRESENT ALSO IN THE UPWARD
AREA
z
Obstacles at rear and above only
z
Obstacles at rear, sides, and above
only
*
100 or
more
Max.
500
1000 or
more
1500 or
more
80 or
more
100 or more
300 or
more
*
: When side walls are protruding frontward, refer to "3-4. DUCT INSTALLATION".
- (03 - 05) -
OU
TD
OO
R
UN
IT
S
OU
TD
OO
R
UN
IT
S
Содержание AB* A12GATH
Страница 1: ...DESIGN TECHNICAL MANUAL ...
Страница 3: ...1 GENERAL INFORMATION DTV_J3LE050E_03 CHAPTER01 2017 10 31 ...
Страница 20: ...2 MODEL SELECTION DTV_J3LE050E_03 CHAPTER02 2017 10 31 ...
Страница 115: ...3 OUTDOOR UNITS DTV_J3LE050E_02 CHAPTER03 2017 07 21 ...
Страница 119: ... Unit mm Detail B Detail A Detail C 03 03 OUTDOOR UNITS OUTDOOR UNITS ...
Страница 128: ...5 WIRING DIAGRAM MODELS AJ 072LELAH AJ 090LELAH 03 12 OUTDOOR UNITS OUTDOOR UNITS ...
Страница 129: ... MODEL AJ 108LELAH 03 13 OUTDOOR UNITS OUTDOOR UNITS ...
Страница 133: ... SOUND LEVEL CHECK POINT Microphone Airflow 1 m 03 17 OUTDOOR UNITS OUTDOOR UNITS ...
Страница 136: ...4 INDOOR UNITS DTV_VR2E018E_14 CHAPTER04 2017 10 31 ...
Страница 216: ... Unit mm INSTALLATION PLACE 04 77 INDOOR UNITS INDOOR UNITS ...
Страница 231: ...4 7 MEDIUM STATIC PRESSURE DUCT TYPE MODELS ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH 04 92 INDOOR UNITS INDOOR UNITS ...
Страница 232: ...4 8 HIGH STATIC PRESSURE DUCT TYPE MODEL ARXC36GBTH MODELS ARXC45GATH ARXC60GATH 04 93 INDOOR UNITS INDOOR UNITS ...
Страница 233: ... MODELS ARXC72GBTH ARXC90GBTH ARXC96GATH 04 94 INDOOR UNITS INDOOR UNITS ...
Страница 234: ...4 9 LARGE AIRFLOW DUCT TYPE MODEL ARXN018GLBH 04 95 INDOOR UNITS INDOOR UNITS ...
Страница 235: ... MODELS ARXN024GTBH ARXN030GTBH 04 96 INDOOR UNITS INDOOR UNITS ...
Страница 236: ... MODELS ARXN18GATH ARXN24GATH ARXN30GATH ARXN34GATH ARXN36GATH ARXN45GATH 04 97 INDOOR UNITS INDOOR UNITS ...
Страница 237: ...4 10 FLOOR CEILING TYPE MODELS AB A12GATH AB A14GATH AB A18GATH AB A24GATH 04 98 INDOOR UNITS INDOOR UNITS ...
Страница 238: ...4 11 CEILING TYPE MODELS AB A30GATH AB A36GATH AB A45GATH AB A54GATH 04 99 INDOOR UNITS INDOOR UNITS ...
Страница 241: ...4 14 WALL MOUNTED TYPE MODELS AS A004GTAH AS A007GTAH AS A009GTAH 04 102 INDOOR UNITS INDOOR UNITS ...
Страница 242: ... MODELS AS A012GCAH AS A014GCAH 04 103 INDOOR UNITS INDOOR UNITS ...
Страница 243: ... MODELS AS A04GACH AS A07GACH AS A09GACH AS A12GACH AS A14GACH 04 104 INDOOR UNITS INDOOR UNITS ...
Страница 244: ... MODELS AS A18GBCH AS A24GBCH AS A18GACH AS A24GACH AS A30GACH 04 105 INDOOR UNITS INDOOR UNITS ...
Страница 245: ... MODELS AS A030GTAH AS A034GTAH 04 106 INDOOR UNITS INDOOR UNITS ...
Страница 246: ...4 15 WALL MOUNTED TYPE EEV external model MODELS AS E004GTAH AS E007GTAH AS E009GTAH 04 107 INDOOR UNITS INDOOR UNITS ...
Страница 247: ... MODELS AS E012GCAH AS E014GCAH 04 108 INDOOR UNITS INDOOR UNITS ...
Страница 248: ... MODELS AS E04GACH AS E07GACH AS E09GACH AS E12GACH AS E14GACH 04 109 INDOOR UNITS INDOOR UNITS ...
Страница 466: ...5 CONTROL SYSTEM DTV_VR2E018E_12 CHAPTER05 2017 10 31 ...
Страница 690: ...6 SYSTEM DESIGN DTV_J3LE050E_03 CHAPTER06 2017 10 31 ...
Страница 779: ...7 FUNCTION SETTING DTV_VR2E018E_14 CHAPTER07 2017 10 31 ...
Страница 975: ...8 EXTERNAL INPUT OUTPUT DTV_VR2E018E_11 CHAPTER08 2017 10 31 ...
Страница 1016: ...9 NOTES DTV_VR2E018E_11 CHAPTER09 2017 07 21 ...
Страница 1034: ...10 OPTIONAL PARTS DTV_VR2E018E_13 CHAPTER10 2017 10 31 ...
Страница 1046: ... 10 11 OPTIONAL PARTS OPTIONAL PARTS z zDimensions Liquid pipe Discharge gas pipe Suction gas pipe 130 15 REDUCER 95 15 REDUCER ...
Страница 1058: ... 10 23 OPTIONAL PARTS OPTIONAL PARTS z zDimensions Liquid pipe Dis charge gas pipe Suction gas pipe ...
Страница 1060: ... 10 25 OPTIONAL PARTS OPTIONAL PARTS z zDimensions Liquid pipe Dis charge gas pipe Suction gas pipe ...
Страница 1068: ... 10 33 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX04BH Unit mm ...
Страница 1073: ... 10 38 OPTIONAL PARTS OPTIONAL PARTS 5 5 WIRING DIAGRAMS MODEL UTP RX01AH MODEL UTP RX01BH ...
Страница 1074: ... 10 39 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX01CH ...
Страница 1075: ... 10 40 OPTIONAL PARTS OPTIONAL PARTS MODEL UTP RX04BH ...