background image

En-4

6.6. Cutting the hole in the wall for the connecting piping

(1)  Cut a 65 mm diameter hole in the wall at the position shown in the following.
(2)  Cut the hole so that the outside end is lower (5 to 10 mm) than the inside end.
(3)  Always align the center of the wall hole. If misaligned, water leakage will occur.
(4)  Cut the wall pipe to match the wall thickness, stick it into the wall cap, fasten the cap with 

vinyl tape, and stick the pipe through the hole.

(5)  For left piping and right piping, cut the hole a little lower so that drain water will 

fl

 ow 

freely. 

Wall

Fasten with 
vinyl tape

65 mm dia. hole

65 mm dia. hole

Wall hook bracket

Center mark

Center mark

Wall cap*

Wall pipe*

(Inside)

(Outside)

5 to 10 mm low

*Field supplied

 WARNING

If the wall pipe is not used, the cable interconnecting the indoor unit(s) and outdoor unit 
or branch box may touch metal and cause electric discharge.

6.7. Installing the wall hook bracket

(1) Install the wall hook bracket so that it is correctly positioned horizontally and vertically. 

If the wall hook bracket is titled, water will drip to the 

fl

 oor.

(2) Install the wall hook bracket so that it is strong enough to support the weight of the 

unit.

• Fasten the wall hook bracket to the wall with 5 or more screws through the holes near the 

outer edge of the bracket.

• Check that there is no rattle at the wall hook bracket.

Wall hook bracket

Tapping screw

 CAUTION

Install the wall hook bracket level, both horizontally and vertically.

6.8. Forming the drain hose and pipe

[Rear piping, Right piping, Bottom piping]

• Install the indoor unit piping in the direction of the wall hole and bind the drain hose 

and pipe together with vinyl tape.

• Install the piping so that the drain hose is at the bottom.
• Wrap the pipes of the indoor unit that are visible from the outside with decorative tape.

[For Left rear piping, Left piping]

Interchange the drain cap and the drain hose.

 CAUTION

Insert drain hose and drain cap securely. Drain should slope down to avoid water 
leakage.

When inserting, be sure not to attach any material besides water. If any other 
material is attached, it will cause deterioration and water leakage.

After removing drain hose, be sure not to forget mounting drain cap.

Be sure to 

fi

 x the drain hose with tape to the bottom of piping.

Prevent drain water freezing under low temperature environment.
When installing indoor unit’s drain hose outdoors, necessary measure for frost 
protection should be taken to prevent drain water freezing.
Under low temperature environment (when outdoor temperature under 0 °C), after 
cooling operation is executed, water in the drain hose could be frozen. Once drain 
water is frozen, the drain hose will be blocked and water leakage may result at the 
indoor unit.

Installation method of Drain cap 

Use a hexagonal wrench 4 mm at opposite side to insert 
the drain cap, till the drain cap contacts the tip of drain 
cock.

Right piping

Bottom piping

Bind with vinyl tape

Refrigerant pipes (top)

Rear piping

Indoor unit drain hose (bottom)

For left outlet piping, 

cut off the piping 

outlet cutting groove 

with a hacksaw. 

Indoor unit 

drain hose

Drain cap

Remove the drain cap by pulling 

at the projection at the end of the 

cap with pliers, etc.

Removal method of drain hose

Remove the screw at the left of 
drain hose and pull out drain hose.

Installation method of drain hose

Vertically insert the drain hose toward the 
inside, so that the drain 

fi

 xture (white) can ac-

curately align with the screw hole around the 
drain cock.
After inserting and before replacing, please 
reinstall and 

fi

 x the removed screws.

•  Please hold around the joint of the drain hose during working.
•  As the screw is inside, be sure to use screwdriver treated with magnet.

Screw

Drain 

fi

xture

Drain hose

Screw hole

Drain cock

Drain hose

Screw

Drain 

fi

xture

• For left piping and left rear piping, align the marks on the wall hook bracket and shape the 

connection pipe.

• Bend the connection piping at a bend radius of 70 mm or more and install no more than 

35 mm from the wall.

• After passing the indoor piping and drain hose through the wall hole, hang the indoor unit on 

the hooks at the top and bottom of the wall hook bracket.

No gap

Hexagonal 
wrench

Drain 

cock

Drain cap

9319357003-02_IM_EN.indd   4

9319357003-02_IM_EN.indd   4

7/27/2011   3:41:55 PM

7/27/2011   3:41:55 PM

Содержание 9319357003-02

Страница 1: ...r autorisiertes Personal MANUEL D INSTALLATION Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION MANUAL AIR CONDITIONER INDOOR UNIT Compact Wall Mounted Type PART NO 9319357003 02...

Страница 2: ... the power always wait 5 minutes before touching electrical components This unit contains no user serviceable parts Always consult authorized service person nel to repairs When moving consult authorized service personnel for disconnection and installation of the unit 2 ABOUT THE UNIT 2 1 Precautions for using R410A refrigerant The basic installation work procedures are the same as conventional ref...

Страница 3: ...utput port Communication kit UTY TWBXF For the installation of optional parts Optional communication kit is necessary for the installation 3 GENERAL SPECIFICATION This installation manual briefly outlines where and how to install the air conditioning system Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system ...

Страница 4: ...ear a source of heat steam or flammable gas Install the unit where drainage does not cause any trouble Install the indoor unit outdoor unit branch box power supply cable transmission cable and remote control cable at least 1 m away from a television or radio receivers The purpose of this is to prevent TV reception interference or radio noise Even if they are installed more than 1 m apart you could...

Страница 5: ...serting be sure not to attach any material besides water If any other material is attached it will cause deterioration and water leakage After removing drain hose be sure not to forget mounting drain cap Be sure to fix the drain hose with tape to the bottom of piping Prevent drain water freezing under low temperature environment When installing indoor unit s drain hose outdoors necessary measure f...

Страница 6: ... table for flaring with R410A flare tools to achieve the specified flaring Use a thickness gauge to measure the dimension A Width across flats Pipe outside diameter mm in Width across flats of Flare nut mm 6 35 1 4 17 9 52 3 8 22 12 70 1 2 26 15 88 5 8 29 19 05 3 4 36 6 9 2 Bending pipes If pipes are shaped by hand be careful not to collapse them Do not bend the pipes in an angle more than 90 When...

Страница 7: ... when wiring cable When stripping off the insulation of a lead wire always use a special tool such as a wire stripper If there is no special tool available carefully strip the insulation with a knife etc 1 Use crimp type terminals with insulating sleeves as shown in the figure below to con nect to the terminal block 2 Securely clamp the crimp type terminals to the wires using an appropriate tool s...

Страница 8: ...pipe heat insulation and indoor unit pipe heat insulation and bind them with vinyl tape so that there is no gap For left and left rear piping butt the connection pipe heat insulation and indoor unit pipe heat insulation together and bind them with and vinyl tape so that there is no gap For left and left rear piping wrap the area which accommodates the rear piping housing section with cloth tape Fo...

Страница 9: ...ditioner operation 2 Press the MODE button and the FAN button simultaneously for 2 seconds or more to start the test run Test run display 3 Press the start stop button to stop the test run 11 REMOTE CONTROLLER INSTALLATION CAUTION Check that the indoor unit correctly receives the signal from the remote controller then install the remote controller holder Select the remote controller holder selecti...

Страница 10: ...hite Black Black Insulated connection Connector 3 0 m m 3 5 4 5 m m 7 0 8 0 m m Installing the wired remote controller terminal sold separately Connect the wired remote controller terminal to the connector CNC01 on the relay control board Relay wire Connector CNC01 Wired remote controller cord Rib 12 1 Accessories Communication kit The following installation accessories are supplied Use them as re...

Страница 11: ...epending on the installed environment the room temperature sensor may require a cor rection The settings may be selected as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 30 00 Slightly lower control 01 Lower control 02 Warmer control 03 Function number Setting value Installing the external connect kit terminal sold separately Connect the wire o...

Страница 12: ...ensor error 7 4 Outdoor temp sensor error 7 5 Suction Gas temp sensor error Heating Room Temperature Correction Depending on the installed environment the room temperature sensor may require a cor rection The settings may be changed as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 31 00 Lower control 01 Slightly warmer control 02 Warmer control...

Страница 13: ...ion detection error 9 7 Outdoor unit fan motor error 9 9 4 way valve error 10 1 Discharge temp error 10 3 Compressor temp error 10 4 High pressure error 10 5 Low pressure error 13 2 Branch boxes error Flexible Multi Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Troubleshooting with the indoor unit display OPERATION indicator lamp green TIMER indicator lamp orange ECONOMY indica...

Отзывы: