2.3. For authorized service personnel only.

 WARNING

For the air conditioner to operate satisfactorily, install it as outlined in this installation 
manual.

Connect the indoor unit and outdoor unit or branch box with the air conditioner piping 
and cables available from your local distributor. This installation manual describes the 
correct connections using the installation set available from your local distributor.

Do not turn on the power until all installation work is complete.

 CAUTION

This installation manual describes how to install the indoor unit only. 
To install the outdoor unit or branch box, refer to the installation manual included with 
the outdoor unit or branch box.

•  Be careful not to scratch the air conditioner when handling it.
•  After installation, explain correct operation to the customer, using the operating manual.

2.4. Accessories

The following installation accessories are supplied. Use them as required.

Name and Shape

Q’ty

Name and Shape

Q’ty

Operating manual

1

Remote controller 

holder

1

Installation manual 

(This manual)

1

Cloth tape

1

Wall hook bracket

1

Tapping screw
(M4 × 25 mm)

5

Remote controller

1

Tapping screw
(M3 × 12 mm)

2

Battery

2

Air cleaning filter

2

Seal A

It is used when the diameter of 
gas pipe is Ø12.70 or more.
It is necessary when using AS14.

1

The following items are necessary to install this air conditioner. (The items are not included 
with the air conditioner and must be purchased separately.)

Name Q’ty

Name Q’ty

Connection pipe assembly

1

Wall cap

1

Connection cable (4-conductor)

1

Saddle

1 set

Wall pipe

1

Drain hose

1

Decorative tape

1

Tapping screws

1 set

Vinyl tape

1

Sealant

1

2.5. Optional parts

Refer to each installation manual for the method of installing optional parts.

Parts name

Model No.

Application

Wired remote controller *

UTY-RNN

¾

M

For air conditioner operation

Simple remote controller *

UTY-RSN

¾

M

For air conditioner operation

External connect kit *

UTY-XWZXZ5

For control input/output port

Communication kit

UTY-TWBXF

For the installation of optional parts

* Optional communication kit is necessary for the installation.

3. GENERAL SPECIFICATION

This installation manual brie

fl

 y outlines where and how to install the air conditioning system. Please 

read over the entire set of instructions for the indoor and outdoor units and make sure all accessory 
parts listed are with the system before beginning.

3.1. Type of copper pipe and insulation material

 CAUTION

Refer to the installation manual for the outdoor unit for description of allowable pipe length 
and height difference.

Selecting pipe sizes

The diameters of the connection pipes according to the capacity of the indoor unit.
Refer to the following table for the proper diameters of the connection pipes between the 
indoor unit and outdoor unit or branch box.

Capacity of indoor unit

Gas pipe size (thickness) 

[mm]

Liquid pipe size (thickness) 

[mm]

7, 9, 12

Ø 9.52(0.8)

Ø 6.35(0.8)

14

Ø 12.70(0.8)

Ø 6.35(0.8)

 CAUTION

Install heat insulation around both the gas and liquid pipes. Failure to do so may 
cause water leaks.
Use heat insulation with heat resistance above 120 °C. Reverse cycle model only)
In addition, if the humidity level at the installation location of the refrigerant piping is 
expected to exceed 70%, install heat insulation around the refrigerant piping. If the 
expected humidity level is 70-80%, use heat insulation that is 15 mm or thicker and if 
the expected humidity exceeds 80%, use heat insulation that is 20 mm or thicker.
If heat insulation is used that is not as thick as speci

fi

 ed, condensation may form on the surface 

of the insulation.
In addition, use heat insulation with heat conductivity of 0.045 W/(m•K) or less 20 °C.

3.2. Additional materials required for installation

A. Refrigeration (armored) tape
B. Insulated staples or clamps for connecting wire (See your local electrical codes.)
C. Putty
D. Refrigeration lubricant
E. Clamps or saddles to secure refrigerant piping

4. ELECTRICAL REQUIREMENT

The indoor unit is powered from the outdoor unit or branch box. Do not power indoor unit 
from separate power source.

 WARNING

Refer to local codes for acceptable cable type.

9319357003-02_IM_EN.indd   2

9319357003-02_IM_EN.indd   2

7/27/2011   3:40:47 PM

7/27/2011   3:40:47 PM

Содержание 9319357003-02

Страница 1: ...r autorisiertes Personal MANUEL D INSTALLATION Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION MANUAL AIR CONDITIONER INDOOR UNIT Compact Wall Mounted Type PART NO 9319357003 02...

Страница 2: ... the power always wait 5 minutes before touching electrical components This unit contains no user serviceable parts Always consult authorized service person nel to repairs When moving consult authorized service personnel for disconnection and installation of the unit 2 ABOUT THE UNIT 2 1 Precautions for using R410A refrigerant The basic installation work procedures are the same as conventional ref...

Страница 3: ...utput port Communication kit UTY TWBXF For the installation of optional parts Optional communication kit is necessary for the installation 3 GENERAL SPECIFICATION This installation manual briefly outlines where and how to install the air conditioning system Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system ...

Страница 4: ...ear a source of heat steam or flammable gas Install the unit where drainage does not cause any trouble Install the indoor unit outdoor unit branch box power supply cable transmission cable and remote control cable at least 1 m away from a television or radio receivers The purpose of this is to prevent TV reception interference or radio noise Even if they are installed more than 1 m apart you could...

Страница 5: ...serting be sure not to attach any material besides water If any other material is attached it will cause deterioration and water leakage After removing drain hose be sure not to forget mounting drain cap Be sure to fix the drain hose with tape to the bottom of piping Prevent drain water freezing under low temperature environment When installing indoor unit s drain hose outdoors necessary measure f...

Страница 6: ... table for flaring with R410A flare tools to achieve the specified flaring Use a thickness gauge to measure the dimension A Width across flats Pipe outside diameter mm in Width across flats of Flare nut mm 6 35 1 4 17 9 52 3 8 22 12 70 1 2 26 15 88 5 8 29 19 05 3 4 36 6 9 2 Bending pipes If pipes are shaped by hand be careful not to collapse them Do not bend the pipes in an angle more than 90 When...

Страница 7: ... when wiring cable When stripping off the insulation of a lead wire always use a special tool such as a wire stripper If there is no special tool available carefully strip the insulation with a knife etc 1 Use crimp type terminals with insulating sleeves as shown in the figure below to con nect to the terminal block 2 Securely clamp the crimp type terminals to the wires using an appropriate tool s...

Страница 8: ...pipe heat insulation and indoor unit pipe heat insulation and bind them with vinyl tape so that there is no gap For left and left rear piping butt the connection pipe heat insulation and indoor unit pipe heat insulation together and bind them with and vinyl tape so that there is no gap For left and left rear piping wrap the area which accommodates the rear piping housing section with cloth tape Fo...

Страница 9: ...ditioner operation 2 Press the MODE button and the FAN button simultaneously for 2 seconds or more to start the test run Test run display 3 Press the start stop button to stop the test run 11 REMOTE CONTROLLER INSTALLATION CAUTION Check that the indoor unit correctly receives the signal from the remote controller then install the remote controller holder Select the remote controller holder selecti...

Страница 10: ...hite Black Black Insulated connection Connector 3 0 m m 3 5 4 5 m m 7 0 8 0 m m Installing the wired remote controller terminal sold separately Connect the wired remote controller terminal to the connector CNC01 on the relay control board Relay wire Connector CNC01 Wired remote controller cord Rib 12 1 Accessories Communication kit The following installation accessories are supplied Use them as re...

Страница 11: ...epending on the installed environment the room temperature sensor may require a cor rection The settings may be selected as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 30 00 Slightly lower control 01 Lower control 02 Warmer control 03 Function number Setting value Installing the external connect kit terminal sold separately Connect the wire o...

Страница 12: ...ensor error 7 4 Outdoor temp sensor error 7 5 Suction Gas temp sensor error Heating Room Temperature Correction Depending on the installed environment the room temperature sensor may require a cor rection The settings may be changed as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 31 00 Lower control 01 Slightly warmer control 02 Warmer control...

Страница 13: ...ion detection error 9 7 Outdoor unit fan motor error 9 9 4 way valve error 10 1 Discharge temp error 10 3 Compressor temp error 10 4 High pressure error 10 5 Low pressure error 13 2 Branch boxes error Flexible Multi Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Troubleshooting with the indoor unit display OPERATION indicator lamp green TIMER indicator lamp orange ECONOMY indica...