Parameter Data Formats
4-16
C141-C010
c. Parameters specifying sector format (bytes 12 to 19)
•
Data byte length/physical sectors
This parameter specifies the data length per 1 physical sector as the number of bytes. In the
IDD, the data byte length per 1 physical sector is the same as the data byte length in 1 logical
data block. The INIT can specify the value of this parameter at 0 or 512 to 528 bytes (4-byte
boundary).
If a value less than 512 bytes, the IDD sets a byte length of 512. If more than 528 bytes is
specified, the IDD performs rounding processing and sets a byte length of 528. If an odd
number of bytes is specified within the specified range, the IDD performs rounding up
processing. If the above rounding processing is performed, the IDD reports the CHECK
CONDITION status (RECOVERED ERROR [=1] / Rounded parameter [37-00] for that
command.
If 0 is specified in this parameter, the value calculated based on the value of the "Data block
length" in the block descriptor is used as this parameter value.
When both this page descriptor and the block descriptor are specified by the same MODE
SELECT command, and a nonzero value is specified in this parameter which differs from the
value in the "Data block length" parameter in the block descriptor, the value specified in the
block descriptor has priority.
•
Interleave factor
This parameter field has meaning only with the MODE SENSE and MODE SENSE
EXTENDED commands. The interleave factor (in the IDD, this is always X '0001' :non
interleave) of the disk drive's current data format. The value specified in this field is
disregarded in the MODE SELECT and MODE SELECT EXTENDED commands.
•
Track skew factor
This parameter indicates the number of physical sectors existing between the data block with the
highest order logical block address on a track and the data block with the next logical block
address on the next track of the same cylinder (track skew). This parameter cannot be changed.
The IDD disregards the value specified in this field and sets the optimum track skew value in the
specified data block length. See Chapter 3, "Data Format" in the Product Manual for details about
track skew. This parameter indicates the value of zone specified in active notch of Page C. If it is
0, this parameter indicates the value in zone 0.
•
Cylinder skew factor
This parameter indicates the number of physical sectors existing between the data block with
the highest order logical block address in a cylinder and the data block with the next logical
block address in the next cylinder (cylinder skew). This parameter cannot be changed. The IDD
disregards the value specified in this field and sets the optimum cylinder skew value in the
specified data block length. See Chapter 3, "Data Format" in the Product Manual for details
about cylinder skew. This parameter indicates the value of zone specified in active notch of
Page C. If it is 0, this parameter indicates the value in zone 0.
d. Parameters related to device type (byte 20)
•
SSEC (soft sectoring)
When this bit is "1," it indicates that the data formatting method on the disk media is "soft
sectoring." However, since the IDD uses only the "hard sectoring" method (refer to previously
shown item b), this bit is disregarded. Furthermore, it is impossible to change this parameter.
Содержание 80
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 18: ...This page is intentionally left blank ...
Страница 62: ...This page is intentionally left blank ...
Страница 284: ...Sense Data Error Recovery Methods This page is intentionally left blank ...
Страница 296: ...This page is intentionally left blank ...
Страница 298: ...This page is intentionally left blank ...
Страница 308: ...This page is intentionally left blank ...
Страница 309: ......
Страница 310: ......