Command Specifications
3-32
C141-C010
(Operations depending on page code and subpage code)
Page code
Subpage code
Operation
00h
Vender Specific (No page format is required.)
-
Reports the contents of the header (if required) and block descriptor.
00h
01h – FFh
Vender Specific (No page format is required.)
-
Terminates with an error (5/24/00).
00h Page_0
Format
-
Reports the contents of the specified pages (excluding page 19).
-
For page 19, reports the contents of subpage X'00' (Short Page).
01h – DFh
Sub_Page Format
-
For pages excluding page 19, terminates with an error (5/24/00).
-
For page 19, reports the contents of subpages X'01', X'03', and X'04' (Long
Page). For other pages, terminates with an error (5/24/00).
E0h – DFh
Vender Specific (Sub_Page Format)
-
Terminates with an error (5/24/00).
01 – 1Fh
FFh
Reports the contents of subpage X'00' (Page_0 Format) of the specified page and
all subpages X01' to X'FE' (Sub_Page Format).
-
For pages excluding page 19, terminates with an error (5/24/00).
-
For page 19, reports the contents of all subpages X'00', X'01', X'03', and X'04'
(Short, Long Page).
00h
Vender Specific (Page_0 Format)
-
Same as "page code X'01' - X'1F' "
01 - FEh
Vender Specific (Sub_Page Format)
-
Same as "page code X'01' - X1F' "
20h – 3Eh
FFh
Reports the contents of subpage X'00' (Page_0 Format) of the specified page and
all subpages X'01' - X'FE' (Sub_Page Format).
-
Same as "page code X'01' - X'1F' "
00h
Reports the contents of all pages or subpage X00' (Page_0 Format).
-
Reports the contents of all supported pages. For page 19, the contents of
subpage X'00' (Short Page) are reported.
01h – FEh
Reserved
-
Terminates with an error (5/24/00).
3Fh
FFh
Reports all pages or subpage X'00' (Page_0 Format) and all subpages X'01' -X'FE'
(Sub_Page Format).
-
Reports the contents of all supported pages. For page 19, all subpages X'00',
X'01', X'03', and X'04' (Short, Long Page) are reported.
Remark:
For Page_0 Format and Sub_Page Format, see the description below.
The
"
PC (page control)
"
field of CDB byte 2 specifies the type of parameter value in the
"
page
descriptor
"
transferred by this command to an INIT
Note:
Even in cases where the value specified in the MODE SELECT or MODE SELECT EXTENDED
command is described in Table 3.1 as the value reported to the INIT by this command, if parameter
rounding processing is applied by the IDD, or in cases of a parameter or bit with a specified value
that is disregarded, different values than those specified by the INIT will be reported. For details, see
the descriptions of each page descriptor (in Section 3.1.5). Also, "0" is reported in byte positions and
bit positions which are reserved in each page descriptor.
Содержание 80
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 18: ...This page is intentionally left blank ...
Страница 62: ...This page is intentionally left blank ...
Страница 284: ...Sense Data Error Recovery Methods This page is intentionally left blank ...
Страница 296: ...This page is intentionally left blank ...
Страница 298: ...This page is intentionally left blank ...
Страница 308: ...This page is intentionally left blank ...
Страница 309: ......
Страница 310: ......