FCR PRIMA T2 Operation Manual 897N102546
For Safe Operation
1
Guidance and manufacturer’s declaration - electromagnetic emissions
The CR-IR 392 is intended for use in the electromagnetic environment specified below.
The customer or the user of the CR-IR 392 should assure that it is used in such an environment.
Emissions test
Compliance
Electromagnetic environment - guidance
RF emissions
CISPR 11
EN 55011
Group 1
The CR-IR 392 uses RF energy only for its internal function.
Therefore, its RF emissions are very low and are not likely to cause any
interference in nearby electronic equipment.
RF emissions
CISPR 11
EN 55011
Class A
The CR-IR 392 is suitable for use in all establishments other than
domestic and those directly connected to the public low-voltage power
supply network that supplies buildings used for domestic purposes.
Harmonic emissions
IEC 61000-3-2
EN 61000-3-2
Class A
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
EN 61000-3-3
Complies
Guidance and manufacturer’s declaration - electromagnetic immunity
The CR-IR 392 is intended for use in the electromagnetic environment specified below.
The customer or the user of the CR-IR 392 should assure that it is used in such an environment.
Immunity test
IEC 60601 test level
Compliance level
Electromagnetic environment -
guidance
Electrostatic discharge
(ESD)
IEC 61000-4-2
EN 61000-4-2
±6 kV contact
±8 kV air
±2 kV contact
±4 kV contact
±6 kV contact
±2 kV air
±4 kV air
±8 kV air
Floors should be wood, concrete or
ceramic tile. If floors are covered with
synthetic material, the relative humidity
should be at least 30%.
Electrical fast
transient/burst
IEC 61000-4-4
EN 61000-4-4
±2 kV for power supply
lines
±1 kV for input/output
lines
±2 kV for power supply
lines
±1kV for input/output
lines
Mains power quality should be that
of a typical commercial or hospital
environment.
Surge
IEC 61000-4-5
EN 61000-4-5
±1kV Line to Line
±2kV Line to Ground
±1 kV Line to Line
±2 kV Line to Ground
Mains power quality should be that
of a typical commercial or hospital
environment.
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines
IEC 61000-4-11
EN 61000-4-11
<5%
U
T
(>95% dip in
U
T
)
for 0.5 cycle
40% UT
(60% dip in
U
T
)
for 5 cycles
70% UT
(30% dip in
U
T
)
for 25 cycles
<5%
U
T
(>95% dip in
U
T
)
for 5 s
<5%
U
T
(>95% dip in
U
T
)
for 0.5 cycle
40%
U
T
(60% dip in
U
T
)
for 5 cycles
70%
U
T
(30% dip in
U
T
)
for 25 cycles
<5% UT
(>95% dip in
U
T
)
for 5 s
Mains power quality should be that
of a typical commercial or hospital
environment. If the user of the CR-
IR 392 requires continued operation
during power mains interruptions, it is
recommended that the CR-IR 392 be
powered from an uninterruptible power
supply or a battery.
Power frequency
(50/60 Hz) magnetic
field
IEC 61000-4-8
EN 61000-4-8
3 A/m
3 A/m
Power frequency magnetic fields should
be at levels characteristic of a typical
location in a typical commercial or
hospital environment.
NOTE:
U
T
is the a.c. mains voltage prior to application of the test level.