7. Check Recirculation Flow Rate.
•
Normal recirculation flow should be level
with the top edge of the airlift pumpback line
cut-out spilling into Chamber 1, the
Sedimentation Chamber.
□
8. Check/Set Aeration Balance Control Valve (blue).
•
The default, normal setting for the Aeration
Control Valve is 50%.
•
Visually observe the airflow rates on each
side of the plant by checking to see if bubbles
are evenly distributed on both sides of
Chamber 3, The Aeration Chamber. If there is
an obvious discrepancy in airflow between
the two sides, adjust the Aeration Balance
Control Valve so that the airflow is equal.
Important!
□
9. Check/Set Effluent Airlift Valve (white).
The
Effluent Control Valve is initially set to 40% and there is
typically no need for it to be adjusted under standard
conditions.
□
10. Check Effluent Airlift Pipe.
Check the observation port in the airlift line to see if
there is smooth water flow from the effluent airlift
pump.
If ot, the he k to e sure that there is ’t a
clog in the airlift pipe with a cleaning brush.