2.4 

Operation

 

 

 

Be sure to mount the front cover before turning the power ON. Do not remove the cover when the inverter power is ON.

 

 

Otherwise, an electric shock could occur.

 

 

Do not operate switches with wet hands.

 

 

Doing so could cause electric shock.

 

 

 

If the auto

-

reset function has been selected, the inverter may automatically restart and drive the motor depending on the cause 

of tripping. Design the machinery or equipment so that human safety is ensured at the time of restarting.

 

 

Otherwise, an accident could occur.

 

 

If the stall prevention function (current limiter), automatic deceleration (anti

-

regenerative control), or overload prevention control 

has been selected, the inverter may operate  with acceleration/deceleration or frequency different from the commanded ones. 
Design the machine so that safety is ensured even in such cases.

 

 

The 

 key on the keypad is effective only when the keypad operation is enabled with function code F02 (= 0, 2 or 3). When 

the keypad operation is disabled, prepare an emergency stop switch separately for safe operations.

 

 

If any of the protective functions have been activated, first remove the cause. Then, after checking that the all run commands 
are set to OFF, release the alarm. If the alarm is released while any run commands are set to ON, the inverter may supply the 
power to the motor, running the motor.

 

 

Otherwise, an accident could occur.

 

 

 

If  you  enable  the  “Restart mode  after momentary  power  failure”  (Function code F14  =  3 to  5),  then  the  inverter  automatically 
restarts running the motor when the power is recovered.

 

 

Design the machinery or equipment so that human safety is ensured after restarting.

 

 

If  the  user  configures  the  function  codes  wrongly  without  completely  understanding  this  Instruction  Manual  and  the  FUJI 

-

 

HYDRAULIC  User’s Manual, the motor may rotate with a torque or at a speed not permitted for the machine.

 

 

An accident or injuries could occur.

 

 

Even  if the  inverter  has interrupted  power  to the motor,  if the  voltage  is  applied to the main  circuit  input terminals  L1/R,  L2/S 
and L3/T, voltage may be output to inverter output terminals U, V, and W.

 

  Even if the motor is stopped due to DC braking, voltage is output to inverter output terminals U, V, and W. 

 

An electric shock may occur.

 

 

The  inverter  can  easily  accept  high

-

speed  operation. When  changing  the  speed  setting,  carefully  check  the  specifications  of 

motors or equipment beforehand.

 

 

Otherwise, injuries could occur.

 

 

 

Do not touch the heat sink because it becomes very hot. 

 

 

Doing so could cause burns.

 

 

The DC brake function of the inverter does not provide any holding mechanism.

 

 

Injuries could occur.

 

 

 

Ensure safety before modifying the function code settings.

 

 

Run  commands  (e.g.,  “Run forward” 

FWD

,

 

“Force  to  run”

  FMS

), stop  commands  (e.g.,  “Coast  to  a stop” 

BX

),  and frequency 

change  commands  can  be  assigned  to  digital  input  terminals.  Depending  upon  the  assignment  states  of  those  terminals, 
modifying the function code setting may cause a sudden motor start or an abrupt change in speed.

 

 

When  the  inverter  is  controlled  with  the  digital  input  signals,  switching  run  or  frequency  command  sources  with  the  related 
terminal commands (e.g., 

SS1

SS2

SS4

SS8

Hz2/Hz1

Hz/PID

IVS

LE

 and 

FMS

) may cause a sudden motor start or an 

abrupt change in speed.

 

 

Ensure  safety  before  modifying  customizable  logic  related  function  code  settings  (U  codes  and  related  function  codes)  or 
turning  ON  the  “Cancel  customizable  logic”  terminal  command 

CLC

.  Depending  upon  the  settings,  such  modification  or 

cancellation  of  the  customizable  logic  may  change  the  operation  sequence  to  cause  a  sudden  motor  start  or  an  unexpected 
motor operation.

 

 

If  any  abnormality  is  found  in  the  inverter  or  motor,  immediately  stop  it  and  perform  troubleshooting,  referring  to  the  FUJI 

-

 

HYDRAULIC  User’s Manual.

 

 

An accident or injuries could occur.

 

 

Содержание FUJI-Hydraulic FRN AR Series

Страница 1: ...STARTING GUIDE HYDRAULIC SOLUTION Frequency inverter for hydraulic elevator SG_FUJI_Hydaulic_EN_1 0 9...

Страница 2: ...and 55 kW added 18 02 13 S Ure a 1 0 4 Chapter 4 and 5 are added Contents updated 20 02 13 M A G mez S Ure a S Ure a 1 0 5 Wiring and Operation information is modified 25 03 13 M A G mez S Ure a S Ur...

Страница 3: ...WIRING EXAMPLE 12 6 1 Power Controller 12 6 2 Valves control 13 6 3 Basic wiring diagram 13 7 RUNNING THE MOTOR 14 7 1 Motor parameters 14 7 2 Step by step auto tuning procedure 14 8 SPEEDS SETTING 1...

Страница 4: ...connections wiring operation or maintenance and inspection Ensure you have sound knowledge of the device and familiarize yourself with all safety information and precautions before proceeding to opera...

Страница 5: ...a recommended molded case circuit breaker MCCB or residual current operated protective device RCD earth leakage circuit breaker ELCB with overcurrent protection in the path of each pair of power lines...

Страница 6: ...anual the motor may rotate with a torque or at a speed not permitted for the machine An accident or injuries could occur Even if the inverter has interrupted power to the motor if the voltage is appli...

Страница 7: ...humidity 5 to 95 No condensation Atmosphere The inverter must not be exposed to dust direct sunlight corrosive gases flammable gases oil mist vapor or water drops Pollution degree 2 IEC EN 60664 1 7...

Страница 8: ...pply side primary side according to the following tables Breaking capacity Min 10 kA Rated voltage Min 500 V Power supply voltage Nominal applied motor kW Inverter type Fuse rating A Figure 1 Input po...

Страница 9: ...inverter type is FRN4 0AR1 4E Note A box replaces an alphabetic letter depending on the enclosure A box replaces an alphabetic letter depending on the shipping destination Enclosure M IP21 or L IP55...

Страница 10: ...mming mode This key discards the settings being configured and cancels the screen transition In Alarm mode This key resets the alarm states and switches to Programming mode UP DOWN key which works as...

Страница 11: ...gure press to confirm PRG 2 1 Data Set 2 Data Check 3 Changed Data 4 Data Copy 5 Timer Setup 6 Initialize 3 Use to select 1 Data Set as it is shown on the figure press to confirm PRG 2 1 F Fundamental...

Страница 12: ...saved next parameter is automatically shown in LCD 6 WIRING EXAMPLE 6 1 Power Controller On the following diagram guidance only 1 an example of motor s wiring with and without inverter is shown single...

Страница 13: ...oller side Same philosophy than a classic hydraulic lift can be used Inverter is not working during DOWN direction travel MAINTENANCE travel Same philosophy than UP DOWN travel Speed is controlled by...

Страница 14: ...Measured by auto tuning P04 1 P08 Motor s stator reactance X1 in P12 Motor s slip frequency Hz Depends on the motor Check NOTE Table 7 Motor related parameters NOTE If motor s speed is 3000 rpm means...

Страница 15: ...8 1 Soft start speed Soft start speed is dependent on HIGH speed as it is shown on below example Example If HIGH speed is C08 Soft start speed C16 HIGH speed Soft start speed C08 C16 C09 C17 C10 C18 C...

Страница 16: ...utput function changes the state from ON to OFF when inverter has switched off IGBT s gate circuit It ensures that magnetic contactors will open after current flow is finished In order to have AX func...

Страница 17: ...stop In order to improve the comfort at stopping soft stop parameters can be adjusted as shown in table 13 Function Recommended setting Description F20 0 2 Hz Starting frequency F21 60 DC braking lev...

Страница 18: ...epend on the load so higher load means lower speed and vice versa Speed ON FWD X1 SS1 ON ON Time ON EN1 EN2 ON E31 F07 F08 E11 E10 ON When U29 Power is reached and speed is higher than E31 speed is li...

Страница 19: ...can make a longer creep speed In order to avoid excessive waiting time two different deceleration holding time parameters can be adjusted U49 U59 There are two limit zones Limit 1 and Limit 2 Dependin...

Страница 20: ...High speed U44 U49 ON ALP Figure 10 Deceleration holding time when Limit 1 zone is reached Output frequency Deceleration holding time default setting Upper Limit 1 U44 90 45 Hz U49 0 25 s Lower Limit...

Страница 21: ...on E03 25 E05 17 E06 18 E31 30 Hz U00 1 U06 3001 U07 8006 U11 20 U12 4003 U13 2 U16 2056 U17 8020 U19 20 0 U21 20 U22 2003 U23 2004 U26 2055 U27 2002 U29 Power limit U30 0 10 U31 20 U32 2006 U33 2003...

Страница 22: ...rrectly set APL function may not work as expected Inverter capacity U94 11 kW 0 22 15 kW 0 30 18 5 kW 0 37 22 kW 0 44 30 kW 0 60 37 kW 0 74 45 kW 0 90 55 kW 1 1 Table 16 U94 setting Function Recommend...

Страница 23: ...z See chapter 9 4 1 C08 HIGH LOW MAINTENANCE speed It depends on installation See chapter 8 for additional details C09 HIGH LOW MAINTENANCE speed C10 HIGH LOW MAINTENANCE speed C11 HIGH LOW MAINTENANC...

Страница 24: ...tion 2 60 U56 Step 12 Control Function 23 U57 Step 12 Input 1 2008 U58 Step 12 Input 2 2011 U59 Step 6 Function 1 0 50 s U61 Step 13 Control Function 30 Soft start Configuration See chapter Error No s...

Страница 25: ...of the motor has risen abnormally 0l1 Overload of motor 1 The electronic thermal protection for motor overload detection was activated 0lu Inverter overload The temperature inside the inverter has ris...

Страница 26: ...c europe com www fujielectric europe com Spain Fuji Electric Europe GmbH Sucursal en Espa a Ronda Can Fatj 5 Edifici D Local B Parc Tecnol gic del Vall s 08290 Cerdanyola Barcelona Tel 34 0 935 824 33...

Отзывы: