ABOUT THIS MANUAL 

Fuji  Electric  Europe  GmbH,  looking  forward  to  bring  on  the  market  new  solutions  for  energy  saving,  has 
developed a new starting guide for the implementation of FUJI 

-

 HYDRAULIC  in hydraulic lift applications.

 

The  aim  of  this  starting  guide  is  to  explain  how  to  set  basic  functions  of  FUJI 

-

  HYDRAULIC    useful  for 

hydraulic lift applications. Main functions are: 

 

 

Magnetic Contactors (MC) control.

 

 

Soft start.

 

 

Soft stop.

 

 

Auto Power Limit (APL) function

 

 

1.1 

FUJI 

-

 HYDRAULIC  main features

 

 

FUJI 

-

 HYDRAULIC  main features are:

 

 

Multifunctional keypad as standard.

 

 

Built

-

in EMC filter (EN61800

-

3:2004, category C2).

 

 

Built

-

in DC Reactor. 

 

 

Customizable logic.

 

 

Two enclosure protections available: IP21 / IP55.

 

 

Thanks to IP55 enclosure and knowing that EMC filter and DC reactor are built

-

in, inverter can be installed 

directly in to a wall. It makes FUJI 

-

 HYDRAULIC  a compact solution easy to install.

 

Additionally,  thanks  to  the  inverter’s  vector  control,  ride  comfort  is  improved  and  energy  consumption  is 
reduced. 

 

 

SAFETY INFORMATION 

Read  this  manual  thoroughly  before  proceeding  with  installation,  connections  (wiring),  operation,  or 
maintenance and inspection. Ensure  you have sound knowledge of the device and familiarize  yourself with 
all safety information and precautions before proceeding to operate the inverter.

 

Safety precautions are classified into the following two categories in this manual.

 

 

 

Failure  to heed  the information  indicated by  this symbol may  lead  to  dangerous conditions, 
possibly resulting in death or serious bodily injuries.

 

 

Failure  to heed  the information  indicated by  this symbol may  lead  to  dangerous conditions, 
possibly resulting in minor or light bodily injuries and/or substantial property damage.

 

 

Failure  to  heed  the  information  contained  under  the  CAUTION  title  can  also  result  in  serious 
consequences.  These  safety  precautions  are  of  utmost  importance  and  must  be  observed  at  all 
times.

 

2.1 

Application

 

 

 

This product is designed to drive a three

-

phase induction motor. Do not use it for single

-

phase motors or for other 

purposes.

 

 

Fire or an accident could occur.

 

 

This product may not be used for a life

-

support system or other purposes directly related to the human safety.

 

 

Though  the  product  is  manufactured  under  strict  quality  control,  install  safety  devices  for  applications  where 
serious accidents or property damages are foreseen in relation to the failure of it.

 

 

An accident could occur.

 

Содержание FUJI-Hydraulic FRN AR Series

Страница 1: ...STARTING GUIDE HYDRAULIC SOLUTION Frequency inverter for hydraulic elevator SG_FUJI_Hydaulic_EN_1 0 9...

Страница 2: ...and 55 kW added 18 02 13 S Ure a 1 0 4 Chapter 4 and 5 are added Contents updated 20 02 13 M A G mez S Ure a S Ure a 1 0 5 Wiring and Operation information is modified 25 03 13 M A G mez S Ure a S Ur...

Страница 3: ...WIRING EXAMPLE 12 6 1 Power Controller 12 6 2 Valves control 13 6 3 Basic wiring diagram 13 7 RUNNING THE MOTOR 14 7 1 Motor parameters 14 7 2 Step by step auto tuning procedure 14 8 SPEEDS SETTING 1...

Страница 4: ...connections wiring operation or maintenance and inspection Ensure you have sound knowledge of the device and familiarize yourself with all safety information and precautions before proceeding to opera...

Страница 5: ...a recommended molded case circuit breaker MCCB or residual current operated protective device RCD earth leakage circuit breaker ELCB with overcurrent protection in the path of each pair of power lines...

Страница 6: ...anual the motor may rotate with a torque or at a speed not permitted for the machine An accident or injuries could occur Even if the inverter has interrupted power to the motor if the voltage is appli...

Страница 7: ...humidity 5 to 95 No condensation Atmosphere The inverter must not be exposed to dust direct sunlight corrosive gases flammable gases oil mist vapor or water drops Pollution degree 2 IEC EN 60664 1 7...

Страница 8: ...pply side primary side according to the following tables Breaking capacity Min 10 kA Rated voltage Min 500 V Power supply voltage Nominal applied motor kW Inverter type Fuse rating A Figure 1 Input po...

Страница 9: ...inverter type is FRN4 0AR1 4E Note A box replaces an alphabetic letter depending on the enclosure A box replaces an alphabetic letter depending on the shipping destination Enclosure M IP21 or L IP55...

Страница 10: ...mming mode This key discards the settings being configured and cancels the screen transition In Alarm mode This key resets the alarm states and switches to Programming mode UP DOWN key which works as...

Страница 11: ...gure press to confirm PRG 2 1 Data Set 2 Data Check 3 Changed Data 4 Data Copy 5 Timer Setup 6 Initialize 3 Use to select 1 Data Set as it is shown on the figure press to confirm PRG 2 1 F Fundamental...

Страница 12: ...saved next parameter is automatically shown in LCD 6 WIRING EXAMPLE 6 1 Power Controller On the following diagram guidance only 1 an example of motor s wiring with and without inverter is shown single...

Страница 13: ...oller side Same philosophy than a classic hydraulic lift can be used Inverter is not working during DOWN direction travel MAINTENANCE travel Same philosophy than UP DOWN travel Speed is controlled by...

Страница 14: ...Measured by auto tuning P04 1 P08 Motor s stator reactance X1 in P12 Motor s slip frequency Hz Depends on the motor Check NOTE Table 7 Motor related parameters NOTE If motor s speed is 3000 rpm means...

Страница 15: ...8 1 Soft start speed Soft start speed is dependent on HIGH speed as it is shown on below example Example If HIGH speed is C08 Soft start speed C16 HIGH speed Soft start speed C08 C16 C09 C17 C10 C18 C...

Страница 16: ...utput function changes the state from ON to OFF when inverter has switched off IGBT s gate circuit It ensures that magnetic contactors will open after current flow is finished In order to have AX func...

Страница 17: ...stop In order to improve the comfort at stopping soft stop parameters can be adjusted as shown in table 13 Function Recommended setting Description F20 0 2 Hz Starting frequency F21 60 DC braking lev...

Страница 18: ...epend on the load so higher load means lower speed and vice versa Speed ON FWD X1 SS1 ON ON Time ON EN1 EN2 ON E31 F07 F08 E11 E10 ON When U29 Power is reached and speed is higher than E31 speed is li...

Страница 19: ...can make a longer creep speed In order to avoid excessive waiting time two different deceleration holding time parameters can be adjusted U49 U59 There are two limit zones Limit 1 and Limit 2 Dependin...

Страница 20: ...High speed U44 U49 ON ALP Figure 10 Deceleration holding time when Limit 1 zone is reached Output frequency Deceleration holding time default setting Upper Limit 1 U44 90 45 Hz U49 0 25 s Lower Limit...

Страница 21: ...on E03 25 E05 17 E06 18 E31 30 Hz U00 1 U06 3001 U07 8006 U11 20 U12 4003 U13 2 U16 2056 U17 8020 U19 20 0 U21 20 U22 2003 U23 2004 U26 2055 U27 2002 U29 Power limit U30 0 10 U31 20 U32 2006 U33 2003...

Страница 22: ...rrectly set APL function may not work as expected Inverter capacity U94 11 kW 0 22 15 kW 0 30 18 5 kW 0 37 22 kW 0 44 30 kW 0 60 37 kW 0 74 45 kW 0 90 55 kW 1 1 Table 16 U94 setting Function Recommend...

Страница 23: ...z See chapter 9 4 1 C08 HIGH LOW MAINTENANCE speed It depends on installation See chapter 8 for additional details C09 HIGH LOW MAINTENANCE speed C10 HIGH LOW MAINTENANCE speed C11 HIGH LOW MAINTENANC...

Страница 24: ...tion 2 60 U56 Step 12 Control Function 23 U57 Step 12 Input 1 2008 U58 Step 12 Input 2 2011 U59 Step 6 Function 1 0 50 s U61 Step 13 Control Function 30 Soft start Configuration See chapter Error No s...

Страница 25: ...of the motor has risen abnormally 0l1 Overload of motor 1 The electronic thermal protection for motor overload detection was activated 0lu Inverter overload The temperature inside the inverter has ris...

Страница 26: ...c europe com www fujielectric europe com Spain Fuji Electric Europe GmbH Sucursal en Espa a Ronda Can Fatj 5 Edifici D Local B Parc Tecnol gic del Vall s 08290 Cerdanyola Barcelona Tel 34 0 935 824 33...

Отзывы: