![Fuji Electric FUJI-Hydraulic FRN AR Series Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/fuji-electric/fuji-hydraulic-frn-ar-series/fuji-hydraulic-frn-ar-series_starting-manual_2341872012.webp)
Fuji Electric Europe GmbH
Page 12 of 26
PRG>2>1>F03
Maximum freq
50.
0Hz
25.0~120.0
Def. 50.0Hz
Store 50.0Hz
←
6.
Use
/
to scroll cursor position, use
/
to change the number. Press
to confirm.
↓
/
/
/
PRG>2>1>F03
Maximum freq
* 6
0.0
Hz
Storing...
7.
When “SaveX” is shown, parameter value is
saved in inverter’s internal memory.
↓
PRG>2>1
F:Fundamental
04:Base freq
05
:Rated voltage
06
:Max output V
07
:Acc time1
08
:Dec time1
8.
After value is saved, next parameter is
automatically shown in LCD.
6
WIRING EXAMPLE
6.1
Power (Controller)
On the following diagram (guidance only)
*1
, an example of motor’s wiring with and without inverter is shown
(single wire drawing). In both cases, between mains and motor two contactors must be installed.
*1
In order to simplify wirings, to keep current connection is recommended (retrofit case).
Motor
Mains supply
3ph 400 V
KM1
KM3
KM2
Motor
KM1
KM2
FRE NIC
Hydraulic
Power wiring diagram
without inverter
Power wiring diagram
with inverter
Mains supply
3ph 400 V
Figure 4: Power wiring connection example
Setting range
25.0 to 120.0