![Fuji Electric FUJI-Hydraulic FRN AR Series Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/fuji-electric/fuji-hydraulic-frn-ar-series/fuji-hydraulic-frn-ar-series_starting-manual_2341872015.webp)
Fuji Electric Europe GmbH
Page 15 of 26
8
SPEEDS SETTING
By combinations of digital inputs X1 and X2 speed command is selected. Combinations are shown in table 8:
SS2
(X2)
SS1
(X1)
Speed command
Speed selected
0
0
C08
(HIGH / LOW / MAINTENANCE)
0
1
C09
(HIGH / LOW / MAINTENANCE)
1
0
C10
(HIGH / LOW / MAINTENANCE)
1
1
C11
(HIGH / LOW / MAINTENANCE)
Table 8: Speed selection table
NOTE:
E04 parameter has to be set to 1002 (for additional information check chapter 10).
8.1
Soft start speed
Soft start speed is dependent on HIGH speed as it is shown on below example:
Example:
If HIGH speed is = C08
Soft start speed = C16
HIGH speed
Soft start speed
C08
C16
C09
C17
C10
C18
C11
C19
Table 9: soft start speed table
8.2
Speed profile example
In table 10, an example of setting in lift speed profile is shown. This example follows wiring example shown
in figure 5.
Soft start speed
(C17)
HIGH speed
(C09)
LOW speed
(C08)
MAINTENANCE speed
(C10)
10 Hz
46 Hz
7 Hz
20 Hz
Table 10: Example of speed profile parameters
NOTE:
LOW and MAINTENANCE speed have to be high enough to be able to move the car in UP direction
with full load.