background image

1. Before Using the Product

Thank you for purchasing the FD5000 series. This manual should be passed
on to the person who operates the product. Examine the product for dam-
age caused by transportation or any other defects. If you find any damage or
defects, contact the sales agent from which you purchased the product or
Fuji Electric Instruments Co., Ltd.

1.1 Model Codes

The  model  lineup  of  the  FD5000  series  is  shown  below.  Check  that  the
model  code  and  specifications  of  your  product  match  those  you  specified
when ordering.

Instruction Manual for FD5000 Series

1/12

2. Mounting the Product

2.1 Dimensions for Cutting Panel

Cut the panel for mounting according to the following dimensions.

2.2 Mounting the Product to the Panel

To mount the FD5000 to the panel, remove its fittings and insert it through
the  hole  in  the  front  of  the  panel.  From  the  back  of  the  panel,  fix  the
product  to  the  panel  with  the  fittings.

92

+0.8

-0

45

+0.6

-0

70 mm

min.

120 mm min.

Fuji Electric Instruments Co.,Ltd

(UU-33554)

  2002.09

Fuji Electric Instruments Co.,Ltd.

International Sales Dept.

No.1,Fuji-machi,Hino-city,Tokyo,191-8502 Japan

Phone +81-42-585-6201,6202

Fax +81-42-585-6187

Instruction Manual for FD5000 Series

UU-33555a        12/12

0: None

Output unit

1: Comparison

2: Analog

3: RS-232C

4: RS-485

5: Comparison and analog

6: Comparison, analog, and RS-232C

Display unit

1: Single display

2: Multi display

Power unit

1: 100 to 240 V AC ± 10%

7: Comparison, analog, and RS-485

F

5 X X X - X X

2: 9 to 60 V DC

D

01: DC voltage measuring unit (range 11: ± 99.99 mV)

Input unit

5 X X X - X X

D

03: DC current measuring unit

02: DC voltage measuring unit

04: AC voltage measuring unit (average rms)

 (range 12: ± 999.9 mV ; range 13:  ± 9.999 V)

 (range 11: 99.99 mV; range 12: 999.9 mV)

05: AC voltage measuring unit (average rms)

 (range 14: 99.99 V; range 15: 600 V)

06: AC voltage measuring unit (true rms)

 (range 11: 99.99 mV; range 12: 999.9 mV)

07: AC voltage measuring unit (true rms)

 (range 14: 99.99 V; range 15: 600 V)

08: AC current measuring unit (average rms)

 (range 23: 9.999 mA; range 24: 99.99 mA)

09: AC current measuring unit (average rms)

 (range 23: 9.999 mA; range 24: 99.99 mA)

10: AC current measuring unit (true rms)

 (range 26: 5 A)

11: AC current measuring unit (true rms)

12: Resistance measuring unit
13: Temperature measuring unit (TC)

14: Temperature measuring unit (RTD)

15: Frequency measuring unit

 (inputs: open collector, logic, and magnet)

16: Frequency measuring unit (input: 50 to 500 Vrms)
17: Strain gauze input unit (load cell)

 (range 14: ± 99.99 V ; range 15:  ± 600 V)

18: Process signal measuring unit

 (range 25: ± 999.9 mA)

 (range 13: 9.999 V)

 (range 13: 9.999 V)

 (range 25: 999.9 mA)

 (range 25: 999.9 mA)

 (range 26: 5 A)

 (4 to 20 mA or 1 to 5 V)

 (range 23: ± 9.999 mA; range 24:  ± 99.99 mA)

MODEL FD5000 SERIES

INSTRUCTION MANUAL

(1) Do not apply a voltage or current exceeding the maximum allowable

value; otherwise, it may damage the equipment.

(2) Use a power voltage within the operation range; otherwise, it may

result in a fire, electrical shock, or malfunction.

(3) The contents of this manual are subject to change without notice.

Although the contents of this manual have been prepared with extra

care, if you have any questions, or find errors or missing

information, contact the sales agent from which you purchased the

product or Fuji Electric Instruments Co.,Ltd.

(4)

After reading this manual thoroughly, keep it in a convenient place

for future reference.

(5)

Caution

!

Содержание FD5000 series

Страница 1: ... V range 11 99 99 mV range 12 999 9 mV 05 AC voltage measuring unit average rms range 14 99 99 V range 15 600 V 06 AC voltage measuring unit true rms range 11 99 99 mV range 12 999 9 mV 07 AC voltage measuring unit true rms range 14 99 99 V range 15 600 V 08 AC current measuring unit average rms range 23 9 999 mA range 24 99 99 mA 09 AC current measuring unit average rms range 23 9 999 mA range 24...

Страница 2: ...inal 1 2 3 4 5 Name Description 1 23 Positive input terminal for range 23 9 999 mA 2 24 3 25 No 4 LO 5 Negative input terminal Positive input terminal for range 24 99 99 mA Positive input terminal for range 25 999 9 mA 5 8 mm min 5 8mm min Applicable solderless terminals 1 2 Name Description No 1 HI Input terminal 2 LO Input terminal 1 2 3 4 5 Name Description 1 HI Input terminal for all ranges 2 ...

Страница 3: ...wire for the power input except for range 26 external control and comparison output connectors 2 Tighten the screws for the power input except for range 26 external control and comparison output connectors to a torque of 0 5 to 0 6 Nm 3 Use 16 to 28 AWG wire for the analog output connector Tighten the screws of analog output connector to a torque of 0 22 to 0 25 Nm 4 Caution Instruction Manual for...

Страница 4: ...ment indicators HI 2 GO LO Indicates the result of judgment and turns on if the measured value HI judgment value Indicates the result of judgment and turns on if LO judgment value the measured value HI judgment value Indicates the result of judgment and turns on if the measured value LO judgment value 3 Function indicators ME Turns on if digital zero backup is on PH Turns on if peak hold valley ho...

Страница 5: ...side judgment value setup 500 X X X X H HI HI side hysteresis setup 0 X X X X H LO LO side hysteresis setup 0 X X X X FSC Full scale Indication value setup 1 X X X X X 9999 9999 9999 9999 9999 9999 9999 9999 9999 9999 9999 9999 9999 FIN Full scale input value setup 1 X X X X X 9999 9999 9999 9999 9999 9999 9999 9999 5000 9999 5000 9999 3 OFS Offset indication value setup 1 X X X X X 0 0 0 0 0 0 0 ...

Страница 6: ...g measurement 2 Press the Mode key to change to the peak hold setup mode 3 For a single display unit press the Mode key to change to the parameter information indication The display automatically changes to this indication in about 1 second except right after COND is indicated 4 Press the Increment key a few times to set to Valley Hold 5 Press the Enter key to return to measurement mode Pressing t...

Страница 7: ...ress the Enter or Mode key to return to the measurement mode 5 Press the Shift key change digit and Increment key change numeric value to set 8000 Note The decimal point in the selected digit flashes 3 Press the Mode key while applying pressure that will cause the display to show zero 4 For a single display unit press the Mode key to change to the parameter information indication or 1 Press the Sh...

Страница 8: ...For details on the RS 485 function see the separate manual on communication functions 7 4 RS 232C Interface Function The FD5000 series can be equipped with an RS 232C interface when the meter is provided with an RS 232C unit For details on the RS 232C function see the separate manual on communication functions 8 Specifications and External Dimensions 8 1 Input Specifications 8 1 1DC Voltage Measur...

Страница 9: ...e speed About 1 second Dead zone 0 to 99 digits Crest factor 4 1 at full scale Range Measurement range Indication Highest resolution Input impedance Maximum permissible input Accuracy 23 9 999mA 1µA About 10 100mA Offset 9999 Full scale 0 to 9999 0 5 of FS 20digit 500mA 3A About 1 About 0 1 10µA 99 99mA 999 9mA 100µA 24 25 Input circuit Single ended type Operating system conversion Maximum samplin...

Страница 10: ...o 10s 1s 100ms Renewal time of a display Input type Input voltage lebel Maximum permissible input Open collector Logic Magnet LO 1V or less 5V 2 2 k pull up LO 1V or less HI 2 5 to 15V 0 3 to 30Vp p 30V 15V Duty ratio 50 7 segment LED display character height 14 2 mm on main display and 8 mm on sub display Automatically indicated when the calculated result is negative OL or OL for input signals ou...

Страница 11: ...its ASCII code No procedure Error detection RS 232C RS 485 Start and stop synchronization Full duplex Communication system Communication rate 38400bps 19200bps 9600bps 4800bps 2400bps Start bit 1bit Data length Two wire half duplex Polling selecting system 1 Up to 31 meters log Output 8 3 3 Communicating Function 8 4 External Dimensions 9 Warranty and After service 9 1 Warranty The warranty period...

Страница 12: ... 2002 09 Fuji Electric Instruments Co Ltd International Sales Dept No 1 Fuji machi Hino city Tokyo 191 8502 Japan Phone 81 42 585 6201 6202 Fax 81 42 585 6187 Instruction Manual for FD5000 Series UU 33555a 12 12 ...

Отзывы: