6-27
MHT258a (Engl.)
■
System parameter for RYS-V type (2/2)
No.
Name
Setting range
Initial value
Change
36
to
59
Unused
−
0
−
60
Torque command function select
0: Torque command 1: Speed command (aux.)
0
Power
61
Speed limit select
0: Parameter 1: Speed command terminal
0
Power
62
Torque limit select
0: Parameter 1: Torque command terminal
0
Power
63
Speed command gain
±
0.10 to
±
1.50 times (in 0.01 steps)
1.00
Always
64
Speed command offset
-2000 to +2000 (in 1 steps)
(Individual)
Always
65
Torque command gain
±
0.10 to
±
1.50 times (in 0.01 steps)
1.00
Always
66
Torque command offset
-200 to +200 (in 1 steps)
(Individual)
Always
67
Monitor1 signal assignment
1: Speed command
2: Speed feedback
3: Torque command
4: Position deviation
2
Always
68
Monitor2 signal assignment
1: Speed command
2: Speed feedback
3: Torque command
4: Position deviation
3
Always
69
Monitor1 scale
±
2.0 to
±
10.0V (in 0.1V steps)
7.0
Always
70
Monitor1 offset
-50 to +50 (in 1 steps)
0
Always
71
Monitor2 scale
±
2.0 to
±
10.0V (in 0.1V steps)
6.0
Always
72
Monitor2 offset
-50 to +50 (in 1 steps)
0
Always
73
Monitor1, 2 output form
0: Monitor1(two-way deflection) / Monitor 2 (two-way deflection)
1: Monitor1(one-way deflection) / Monitor 2 (two-way deflection)
2: Monitor1(two-way deflection) / Monitor 2 (one-way deflection)
3: Monitor1(one-way deflection) / Monitor 2 (one-way deflection)
0
Power
74
Unused
−
0
Power
75
Soft OT valid/invalid
0: Valid 1: Invalid
0
Power
76
+Soft OT detection position
-79999999 to 0 to 79999999 (in 1 steps) [x unit q'ty]
79999999
Always
77
-Soft OT detection position
-79999999 to 0 to 79999999 (in 1 steps) [x unit q'ty]
-79999999
Always
78
Pulse train input form
0: Command code/pulse 1:Forward/reverse pulse
2: Two 90
°
phase-different signal
1
Power
79
Output pulse count
16 to 16384 [pulse/rev] (in 1 steps)
2048
Power
80
Rotational direction changeover
0: Positive direction/forward 1: Positive direction/reverse
0
Power
81
Operation at stoppage
0: Speed zero 1: Servo lock 2: Brake (P-action)
3: Brake (free-run)
0
Power
82
Brake operation time
0.01 to 9.99s (in 0.01s steps)
0.50
Always
83
Brake releasing time
0.01 to 9.99s (in 0.01s steps)
0.20
Always
84
Operation at undervoltage
0: Rapidly decelerates to stop 1: Free-run
0
Power
85
Alarm detection at undervoltage
0: No detection 1: Detect
0
Power
86
Resistor thermal relay
0: Electronic thermal relay 1: External thermal relay
0
Power
87
CONT always valid 1
0 to 56 (in 1 steps)
0
Power
88
CONT always valid 2
0 to 56 (in 1 steps)
0
Power
89
Initial indication
0 to 20 (in 1 steps)
0
Power
90
to
93
Unused
−
0
−
94
Parameter rewriting inhibit
0: Rewriting enable 1: Rewriting disable
0
Power
95
Unused
−
0
Power
96
Station number
1 to 31 (in 1 steps)
1
Power
97
Baud rate
0: 9600 1: 19200 2: 38400 [bps]
0
Power
98
Unused
−
0
Power
99
INC/ABS system
0: INC (Incremental) 1: ABS (Absolute)
0
Power
Содержание Faldic-a Series
Страница 1: ...RYS V Type User s Manual MHT258a Engl...
Страница 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Страница 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Страница 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Страница 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...
Страница 234: ...10 22 MHT258a Engl c Resistor type WSR 152 Application RYS type amplifier 1 and 1 5 kW P DB 1 2...