MHT258a (Engl.)
6-24
6.5 List of parameter
Basic parameter
The basic parameters are rather frequently adjusted. Changing almost any basic parameter immediately affects the amplifier and the motor
actions.
■
Basic parameter for RYS-V type (1/2)
Para.
Name
Setting range
Initial value
Change
01
Manual feed speed 1
0.01 to Max. speed [r/min] (in 0.01 steps)
100.00
Always
02
Manual feed speed 2
0.01 to Max. speed [r/min.] (in 0.01 steps)
500.00
Always
03
Manual feed speed 3
0.01 to Max. speed [r/min.] (in 0.01 steps)
1000.00
Always
04
Manual feed speed 4
0.01 to Max. speed [r/min.] (in 0.01 steps)
100.00
Always
05
Manual feed speed 5
0.01 to Max. speed [r/min.] (in 0.01 steps)
100.00
Always
06
Manual feed speed 6
0.01 to Max. speed [r/min.] (in 0.01 steps)
100.00
Always
07
Manual feed speed 7
0.01 to Max. speed [r/min.] (in 0.01 steps)
100.00
Always
08
to
15
Unused
0
−
16
Maximum speed
0.01 to Max. speed [r/min.] (in 0.01 steps)
5000.00
Always
17
Override 1
0 to 150% (in 1% steps)
10
Always
18
Override 2
0 to 150% (in 1% steps)
20
Always
19
Override 4
0 to 150% (in 1% steps)
40
Always
20
Override 8
0 to 150% (in 1% steps)
80
Always
21
Acceleration time 1
0.000 to 99.999s (in 0.001s steps)
0.100
Always
22
Deceleration time 1
0.000 to 99.999s (in 0.001s steps)
0.100
Always
23
Acceleration time 2
0.000 to 99.999s (in 0.001s steps)
0.500
Always
24
Deceleration time 2
0.000 to 99.999s (in 0.001s steps)
0.500
Always
25
Non-linear (Scurve) filter coefficient
0.000 to 99.999s (in 0.001s steps)
0.000
Always
26
to
30
Unused
−
−
−
31
Tuning method
0: Manual 1: Auto(Low stiffness) 2: Auto (High stiffness)
1
Always
32
Load inertia ratio
0.0 to 100. 0 times (in 0.1 steps)
0.0
Always
33
Operation speed response
10 to 1000Hz (in 1Hz steps)
100
Always
34
Speed response at stoppage
10 to 1000Hz (in 1Hz steps)
100
Always
35
Stop detection width
5 to 100 [r/min] (in 1 steps)
20
Always
36
Stop judgment time
0.00 to 1.00s (in 0.01s steps)
0.00
Always
37
Torque filter time constant
0.00 to 20.00 [ms] (in 0.01ms steps)
0.30
Always
38
Speed regulator integration time
1 to 1000 [ms] (in 1 steps)
20
Always
39
Position regulator gain
1 to 1000 (in 1 steps)
50
Always
40
Feed forward gain
0.000 to 1.5000 (in 0.001 steps)
0.000
Always
41
Speed setting filter
0.0 to 20. 0 [ms] (in 0.1 steps)
0.0
Always
42
Speed feedback filter
0: OFF 1: ON
0
Always
43
Torque setting filter
0.0 to 9.9s (in 0.1 steps)
0.1
Always
44
Vibration suppression time constant
10 to 1000 [ms] (in 1 steps)
100
Always
45
Vibration suppression gain
0.00 to 1.00 (in 0.01 steps)
0.00
Always
46
to
50
Unused
−
−
−
Содержание Faldic-a Series
Страница 1: ...RYS V Type User s Manual MHT258a Engl...
Страница 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Страница 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Страница 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Страница 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...
Страница 234: ...10 22 MHT258a Engl c Resistor type WSR 152 Application RYS type amplifier 1 and 1 5 kW P DB 1 2...