MHT258a (Engl.)
9-4
(iii) Step 3 : Indicate the sub-sequence mode display.
(*1) 1[sec] min. (*2) Sequence mode display (*3) Sub-sequence mode display
LC display
Cause and check : At rotational status
Waits for rotation command (above figure).
Executes manual feed.
Pulse train is valid.
Origin return is in progress.
Interrupt position is in progress.
Clears the position deviation.
Positioning control by address designation is in progress.
Brake timing is being measured.
Halts by positioning cancel signal.
Remark : The analog speed command voltage can be checked on the touch panel.
ENT (*1)
ESC
ENT (*1)
(*2)
ESC
(*3)
Motor does not rotate
[CONT] is assigned to positioning cancel and input is
turned on. Reset it.
Sub-sequence display StoP
[CONT] is assigned to positioning cancel and input is
turned on. Reset it.
Sub-sequence display PIn
Assign [CONT] to [FWD] and [REV] and turn on either.
If both are turned on, motor does not rotate.
Sub-sequence display Stnd
Sub-sequence display JoG.
Motor may be rotating.
Basic para. 1 to 7 setting may be too low or [CONT]
X1/X2 input may not correctly be turned on.
Speed set by multistep speed command.
Speed command voltage may be too low.
Check the wiring. Raise the voltage.
Speed command voltage inputted.
Checked by monitor mode On009.
Содержание Faldic-a Series
Страница 1: ...RYS V Type User s Manual MHT258a Engl...
Страница 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Страница 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Страница 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Страница 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...
Страница 234: ...10 22 MHT258a Engl c Resistor type WSR 152 Application RYS type amplifier 1 and 1 5 kW P DB 1 2...