7-6
MHT258a (Engl.)
System parameter 89 setting
Setting
Initial indication
Setting
Initial indication
0
[
]
Sequence
7
[
]
Feedback speed
1
[
]
Sub-mode
8
[
]
Command speed
2
[
]
Alarm detection
9
[
]
Actual torque
3
[
]
Alarm history
10
[
]
Feedback position
4
[
]
Amplifier setting
11
[
]
Command position
5
[
]
Motor setting
12
[
]
Deviation amount
6
[
]
Station No. indication
13
[
]
Cumulated pulse
14
[
]
Peak torque
15
[
]
Input voltage 1
16
[
]
Input voltage 2
17
[
]
LS-Z pulse
18
[
]
Input signal
19
[
]
Output signal
20
[
]
Load inertia ratio
(2) Sub-mode
Indicates the sub-mode of the sequence mode.
ENT (1s or more)
Indication
Description
In base-off condition. The motor does not have
driving force and in free-run status.
The motor can rotate and is waiting run command.
The motor can rotate and is executing manual feed.
The motor can rotate and the pulse train input is valid.
The motor can rotate and is executing positioning
operation.
The motor can rotate and is executing origin return.
The motor can rotate and is executing interrupt
positioning.
The amplifier is executing deviation clear.
The motor can rotate and is measuring the brake
timing.
The motor is stopping with positioning cancel signal.
The amplifier has detected an overtravel signal in
positive direction and stops.
The amplifier has detected an overtravel signal in
negative direction and stops.
ESC
Содержание Faldic-a Series
Страница 1: ...RYS V Type User s Manual MHT258a Engl...
Страница 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Страница 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Страница 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Страница 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...
Страница 234: ...10 22 MHT258a Engl c Resistor type WSR 152 Application RYS type amplifier 1 and 1 5 kW P DB 1 2...