6-15
MHT258a (Engl.)
Remark : Where the motor rotates at 5000[r/min] at output pulse count setting 3000[pulse/rev]
The output pulse count is
3000
60
5000
250000
[
/
]
[ / min ]
[
]
pulse rev
r
Hz
×
=
If the motor rotation exceeds 5000[r/min] at 16384[pulse/rev] max., the pulse count will exceed 1.3[MHz].
6.2.4 Pulse train input
The pulse form of pulse train input terminal can be selected.
The pulse form of pulse train input terminal [CA], [*CA], [CB], [*CB] can be selected. The maximum input frequency is 400kHz.
System parameter 78
Para.
Name
Setting range
Initial value
Change
78
Pulse train input form
0 : Command code, command pulse
1: Forward pulse, reverse pulse
2: Two 90° phase-different signal
1
Power
■
Command pulse, command code
The command pulse indicates rotational quantity and the command code indicates rotational direction.
t
1
t
2
t
3
t
4
Pulse level : t
1
>
1.25
μ
s
Pulse cycle : t
2
≧
2.5
μs
Before sign change : t
3
>
1.25
μ
s
After sign change : t
4
≧
1.25
μ
s
Command code
[CB]
Command pulse
[CA]
■
Forward pulse, reverse pulse
Forward pulse indicates forward direction, reverse pulse indicates the reverse direction.
t
5
t
6
t
7
Reverse pulse
[CB]
Forward pulse
[CA]
Pulse level : t
5
>
1.25
μ
s
Pulse cycle : t
6
≧
2.5
μ
s
Edge interval : t
7
>
1.25
μ
s
Содержание Faldic-a Series
Страница 1: ...RYS V Type User s Manual MHT258a Engl...
Страница 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Страница 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Страница 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Страница 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...
Страница 234: ...10 22 MHT258a Engl c Resistor type WSR 152 Application RYS type amplifier 1 and 1 5 kW P DB 1 2...