38
Usage of CC-Link
Load Data
For hold load values and real time load values, data format changes by setting either
BCD or Binary at Return Data Format.
See Page 58 CC-Link for the setting procedure.
Real time load value and hold load value
MSB
4 bits
Status
See the following figure.
4 bits
Decimal position
0: 0
1: 0.0
2: 0.00
3: 0.000
4: 0.0000
4 bits
Reserved
0
4 bits
5th digit
BCD/Binary
4 bits
4th digit
BCD/Binary
4 bits
3rd digit
BCD/Binary
4 bits
2nd digit
BCD/Binary
LSB
4 bits
1st digit
BCD/Binary
STATUS
Status
Bit3
Bit2
Bit1
Bit0
0
Plus (+)
BCD display
Without input over
Real time load value
1
Minus (
−)
Binary display
With input over
Hold load value
Memory Selection
Setting Memory selection does not work when "Manual" is set by "Select Memory by" in
CC-Link settings. When selecting a setting memory on CC-Link, set Select Memory by to
CC-Link.
See Page 58 CC-Link for details.