32
Connecting CC-Link Terminal
Use a dedicated cable for CC-Link for connection cable.
Connect the shield to SLD terminal.
Connect the end resistance between DA and DB.
Be sure to turn off power prior to wiring.
Be sure to put the terminal cover on after wiring.
Address Map
Remote Resister
DATA MEMORY
Station
Output
Address
Name
Input
Address
Name
Area
1
RWr0000
0x2E0
Hold load value
RWw0000
0x1E0
OF value
(set load arrival
output)
Exclusive
area
RWr0001
0x2E1
RWw0001
0x1E1
RWr0002
0x2E2
Real time load
value
RWw0002
0x1E2
HI value (High
Limit)
RWr0003
0x2E3
RWw0003
0x1E3
2
RWr0004
0x2E4
Reserved
RWw0004
0x1E4
LO value
(Low Limit)
RWr0005
0x2E5
RWw0005
0x1E5
RWr0006
0x2E6
Error code
RWw0006
0x1E6
Reserved
RWr0007
0x2E7
Support error
code
RWw0007
0x1E7
3
RWr0008
0x2E8
Reserved
RWw0008
0x1E8
Reserved
RWr0009
0x2E9
RWw0009
0x1E9
RWr000A
0x2EA
RWw000A
0x1EA
RWr000B
0x2EB
RWw000B
0x1EB
4
RWr000C 0x2EC
Read command
data
RWw000C 0x1EC
Write
command
data
Common
area
RWr000D 0x2ED
RWw000D 0x1ED
RWr000E
0x2EE
Read command
number
RWw000E
0x1EE
Write
command
number
RWr000F
0x2EF
Reserved
RWw000F
0x1EF
Reserved
Be aware that CC-Link receives commands only from the measurement display
screen.