7
FT Input Expander
EN
6. FT Input Expander map
The inputs configured in FT Input Expander will be recorded directly in the
module, and will be completely independent of the map recorded in the ECU.
On the ECU map the inputs can be set as either the reading comes from the
ECU itself or if it comes through the CAN network.
Therefore, despite being independent maps, it is necessary to inform the ECU
which channels will come from FT Input Expander and to do this automatically,
it is necessary that the ECU map is open in the FT Manager before opening
the FT Input Expander map.
After making the desired configurations, just save the settings in the FT Input
Expander and at that moment a message will be displayed, allowing that the
configuration of the inputs on the ECU map is done automatically. Finally,
remember to save the updated map to the ECU.
The FT Input Expander identification file has an extension (.ftie) that is different
from an ECU map file.
7. Configuring the FT Input Expander
After the electrical installation is completed and the CAN network is connected,
you can configure the FT Input Expander inputs. There are two types of
configuration, one for analog / digital inputs and one for frequency readings
such as the RPM and speed channels.
1
3
2