700- LT1-SYS-IG Rev 2 22 Oct 2018
Page 12/22
a)
First, connect the black wire to the battery’s negative (-) terminal.
b)
Second, connect the red wire to the battery’s positive (+) terminal.
The solar regulator LEDs will power up and display green lights. Refer to section 2.7 for
details of the solar regulator LED status indicators.
Use the reverse order to disconnect the battery.
2)
Use the voltmeter to confirm 12 volts is being supplied to the output terminal on which
the LT1 to Regulator Cable Assembly is attached (regulator terminal 2 or 3)
IMPORTANT!
Prior to connecting the LT1, the output from the solar regulator
MUST be disabled.
3)
Press and hold the button on the regulator for at least 3 seconds. The output LED
should turn off and blink on every 2 seconds.
Figure 2-7: Solar Regulator status LEDs and final power connections (LT1-CELL shown)
4)
Insert the terminal block into the LT1.
5)
Turn on the regulator output by quickly pressing the black button on the regulator.
Ensure the Output LED on the solar regulator turns solid On and the LT1 LEDs indicate
there is power.
Press for 3 seconds to disable
output
Quickly press and release to
enable output