background image

User´s manual ꞏ MIND 

Reserved for technical modifications and/or errors

                                                    - 

4

 -                                                   

MIND  

  

Version en_1.0

           

 Fte maximal

 

1  Starting Installation

 

1.1  Safety Rules 

Please read the manual carefully before using the amplifier. 
You will receive a lot of information to use this product correctly and you will prevent incidents.  
Please keep the manual on a safe place.

 

 
 

 

 

This sign warns you about  
high voltages, with risk 
of electric shock

 

Caution

: Do not open the housing of this 

amplifier.  Repairs  can  only  be  made  by 
professionals authorized by Fte maximal. 
If not, warranty will not be valid anymore. 

This  sign  informs  about 
special  information  which  is 
important to know.

 

 
Caution

:  Keep  this  amplifier  far  away  from  liquids.  Do  not  place  it  on  placements  close  to  water  like 

flowers  vases

wash  basin

aquariums

  or  pools.  A  high  risk  of  electric  exists  shock  when  water  or  high 

humidity

 filters inside the amplifiers. Never place other devices on it; they can overheat the amplifiers as 

well as daring fire risk. The amplifiers must be used only with original power cord to 230V main plug.  
Please  read  carefully  this  manual  and  do  not  hesitate  to  contact  to  professional  help  if  you  have  any 
doubt.  

 

Opening the amplifier housing will mean a warranty void. 

 

Installation:  

1. Respect the ventilation holes of the equipment without covering them with any object. 
2. Keep clear the environment of the equipment, with a minimum ratio of 40 cm. 
3. Do not place the equipment close to any heating source. 
4. Do not make the equipment work at any temperature that exceeds the range of working temperatures. 
5. Avoid placements with risk of dumping liquids inside and with big changes in temperature. 
6.  Never  open  the  equipment  by  yourself,  due  to  risk  of  electrocution.  In  case  of  problems,  please  get  always 
qualified technicians. 
7. Never open the equipment while it is plugged to the Power Network. 
8. It is preferable that the equipment is disconnected during the connection of it. 
9.  Respect  the  safety  electrical  rules  during  the  installation.  Use  the  materials  that  perform  the  current 
regulations.  
10. The connection plug must be accessible in an easy and simple mode, and always to get a fast disconnection. 
11. Never touch the power  network plug  with  wet hands. Disconnect always the equipment before handling its 
connections. 
12. Do not place any heavy object over the equipment, due to it could get damaged.  

 

Cleaning

: Before cleaning the amplifier with a slightly 

damped

 

cloth

, please disconnect the main 230 Vac connection 

from the amplifier. Please use only 

mild cleaners.

  

 

Accessories

: Please, do not use accessories which are not agreed by the manufacturer of the amplifier. 

Unsuitable accessories could increase the risk of getting on fire, an electrical impact or other damages. 
 

Placement:

  Select  a  placement  where  the  Amplifiers  has  air  circulation  enough,  otherwise  it  may  have  overheating 

accumulation. 
 

Power connection:

 Select a main plug with easy access, in case of unplugging necessity; it will be easier and faster. 

Please, make sure that the cord as well as the plug is in perfect conditions. Do not pull the cable, use always the plug. 
 

Housing:

 Please, make sure that no liquid will filter into the housing of the amplifier. If so, disconnect immediately the 

amplifier from the main 230 V plug and bring the amplifier to a professional.  
 

Air humidity:

 When you take the Amplifier from a cold to a warm place, please wait until the amplifier gets the same 

temperature as the new environment, in order to avoid problems of humidity condensation.  

 
Maintenance  /  Repairing

:  Within  the  warranty  time  all  the  repairing  processes  should  be  done  by  Fte  Maximal 

technical staff. Otherwise, the warranty will be lost. 

RISK OF ELEKTRIC SHOCK 

DO NOT OPEN

CAUTION

R

Содержание MIND 32

Страница 1: ...v 1 0 MIND User s manual...

Страница 2: ...III UHF4 MODE 10 3 3 Menu DC PASS 10 3 4 Menu AUTO SCANNING 11 3 5 Men UHF1 11 3 6 Menu UHF2 12 3 7 Menu UHF3 13 3 8 Men BIII UHF4 13 3 9 Menu OUT 13 Level 13 Slope 13 3 10 Menu FM 13 Preaamplifier FM...

Страница 3: ...se get always qualified technicians 7 Never open the equipment while it is plugged to the Power Network 8 It is preferable that the equipment is disconnected during the connection of it 9 Respect the...

Страница 4: ...Content of the box When you open the box or the first time you will find the following content User s manual AC Power cord Depending of the model selected you will find the following content in the bo...

Страница 5: ...0 7 F 0 F FM outdoor antenna Code 9002005 F In this example 6 types of antennas can be connected to the programmable amplifier Also pre amplifiers can be connected at UHF inputs All the different elem...

Страница 6: ...on 2 1 Connections MIND 32 1 FM Input for FM aerial 2 UHF 1 UHF2 UHF 3 Input for UHF antenna 3 BIII UHF4 Input for BIII DAB and UHF antenna 4 USB PORT USB port to save and restore configuration backup...

Страница 7: ...t for FM antenna 3 UHF 1 UHF2 UHF 3 Input for Terrestrial UHF antenna 4 BIII UHF4 Input for DAB BIII and UHF antenna 5 USB PORT USB port to save and restore configuration backups 6 SAT Input for IF si...

Страница 8: ...en will appear asking to enter it Select the digits values with keys Press OK button to confirm the values The main menu contains the following options BIII UHF4 MODE Allow configure the bands for the...

Страница 9: ...u DC PASS This menu enables or disables power for preamplifier in the UHF inputs Press OK to edit the voltage value for the preamplifier The voltage value is equal for all inputs Use the buttons of th...

Страница 10: ...SCANNING Use the buttons of the keyboard and select to add the input in the auto scanning If select the input will be not included in the scan Press Ok to confirm the selection Repeat the process wit...

Страница 11: ...one channel with 7 MHz of bandwidth For example the channel UHF has a bandwidth of 8 MHz and the BIII have a bandwidth of 7 MHz If move the channel from UHF to VHF band remember the output channel us...

Страница 12: ...put If the filters were added manually in the UHF and BIII UHF menu remember adjusment the value of Level Press OK to edit the value and use the buttons to select the new value Press OK to confirm Pre...

Страница 13: ...om 0 to 20 dB Press OK to edit the value and keys to change Then press OK to confirm Press to return to the AUX PREAMPLIFIER screen or ESC to go back to the main menu 3 12 Men SAT Satellite configurat...

Страница 14: ...ou can select the satellite band activating or deactivating the 22KHz tone Options High High band o Low Low band Press OK to edit the value and keys to change Then press OK to confirm Press to access...

Страница 15: ...B memory to the USB port of amplifier to access this menu The USB memory must be formatted in a FAT or FAT32 file system Config Export This screen allows you to save the current configuration of the h...

Страница 16: ...K key to confirm it The PIN will be requested from the moment the Nebula comes back from sleep mode Press to access the next screen Language This screen can select the language of the display The opti...

Страница 17: ...M 35 25 dB 1 BIII DAB UHF 55 dB Regulation FM 20 dB Input BIII UHF and UHF 0 20 dB AGC Output level FM 123 dBuV BIII UHF 123 dBuV Preamplifiers feeding In all UHF inputs 0 12 24 VDC 80mA maximum per I...