background image

User´s manual ꞏ MIND 

Reserved for technical modifications and/or errors

                                                    - 

18

 -                                                   

MIND  

  

Version en_1.0

           

 Fte maximal

 

4  Technical specification  

4.1  Technical specification MIND 32 

 

Model 

MIND 32 

Code 

2003410 

Description 

Programable amplifier 32 filters (BIII / UHF) 

Inputs 

FM  

88 – 108 MHz 

BIII/UHF4 

DAB Mode: 

174 – 230 MHz 

BIII-UHF Mode:  174 – 230 MHz/  470- 862 MHz  
 
DAB Mode: 

Use 8 programmable filters available 

BIII-UHF Mode:  32  programmable  filters  with  BW  1 
channel ( 7 MHz* ó 8MHz*)   
The filters are share with the other UHF inputs 

3 x UHF 

470-862 MHz 
32 filters programmable with BW of 1 channel per filter (7 
MHz* or 8MHz*).  
The filters are share with the input  BIII/UHF4 

Input level range

 

FM:  

 

40-90 dBuV 

BIII/ UHF: 

50-100 dBuV 

Outputs 

1 TER + 1 TEST (-30dB) 

Gain: 

FM 

(35/ 25)  dB (1)  

BIII-DAB/UHF 

> 55 dB 

Regulation 

FM: 20 dB / Input BIII-UHF and UHF 0..20 dB + AGC 

Output level 

FM 

123 dBuV 

BIII/UHF 

123 dBuV 

Preamplifiers feeding 

In all UHF inputs 0/12/24 VDC (80mA maximum per Input).  Total current for all 
inputs is 200 mA. 

Equalization 

0..9 dB in step of 1 dB 

Noise figure  

FM  

< 6 dB 

BIII-DAB/UHF 

Selectivity  filters  BIII/UHF 
(± 1 MHz) 

> 35 dB 

LTE/5G filtering 

Yes, using the selectivity extreme of the programmable filters 

Programming 

Through  integrated  programmer  with  5  buttons  and  2-line  LCD  display  of  16 
characters 

Digital 

channel 

conversion 

Yes  

Auto  scan  channels  in 
UHF band 

Yes 

Select 

standard 

and 

region 

Yes 

LCD language  

English and Spanish 

Supply 

100-254Vac 50-60Hz 

Power consumption  

15W  

USB Port 

USB 2.0 to import / export settings 

Temperature 

-5 /+50ºC 

Dimensions 

265mm x 190 mm x 52 mm 

 

1

 

The gain value depends on the On / Off state of the input AMP stage 

The bandwidth of the channel depends of the band.

 
 
 
 
 
 
 
 
 
 
 

 

Содержание MIND 32

Страница 1: ...v 1 0 MIND User s manual...

Страница 2: ...III UHF4 MODE 10 3 3 Menu DC PASS 10 3 4 Menu AUTO SCANNING 11 3 5 Men UHF1 11 3 6 Menu UHF2 12 3 7 Menu UHF3 13 3 8 Men BIII UHF4 13 3 9 Menu OUT 13 Level 13 Slope 13 3 10 Menu FM 13 Preaamplifier FM...

Страница 3: ...se get always qualified technicians 7 Never open the equipment while it is plugged to the Power Network 8 It is preferable that the equipment is disconnected during the connection of it 9 Respect the...

Страница 4: ...Content of the box When you open the box or the first time you will find the following content User s manual AC Power cord Depending of the model selected you will find the following content in the bo...

Страница 5: ...0 7 F 0 F FM outdoor antenna Code 9002005 F In this example 6 types of antennas can be connected to the programmable amplifier Also pre amplifiers can be connected at UHF inputs All the different elem...

Страница 6: ...on 2 1 Connections MIND 32 1 FM Input for FM aerial 2 UHF 1 UHF2 UHF 3 Input for UHF antenna 3 BIII UHF4 Input for BIII DAB and UHF antenna 4 USB PORT USB port to save and restore configuration backup...

Страница 7: ...t for FM antenna 3 UHF 1 UHF2 UHF 3 Input for Terrestrial UHF antenna 4 BIII UHF4 Input for DAB BIII and UHF antenna 5 USB PORT USB port to save and restore configuration backups 6 SAT Input for IF si...

Страница 8: ...en will appear asking to enter it Select the digits values with keys Press OK button to confirm the values The main menu contains the following options BIII UHF4 MODE Allow configure the bands for the...

Страница 9: ...u DC PASS This menu enables or disables power for preamplifier in the UHF inputs Press OK to edit the voltage value for the preamplifier The voltage value is equal for all inputs Use the buttons of th...

Страница 10: ...SCANNING Use the buttons of the keyboard and select to add the input in the auto scanning If select the input will be not included in the scan Press Ok to confirm the selection Repeat the process wit...

Страница 11: ...one channel with 7 MHz of bandwidth For example the channel UHF has a bandwidth of 8 MHz and the BIII have a bandwidth of 7 MHz If move the channel from UHF to VHF band remember the output channel us...

Страница 12: ...put If the filters were added manually in the UHF and BIII UHF menu remember adjusment the value of Level Press OK to edit the value and use the buttons to select the new value Press OK to confirm Pre...

Страница 13: ...om 0 to 20 dB Press OK to edit the value and keys to change Then press OK to confirm Press to return to the AUX PREAMPLIFIER screen or ESC to go back to the main menu 3 12 Men SAT Satellite configurat...

Страница 14: ...ou can select the satellite band activating or deactivating the 22KHz tone Options High High band o Low Low band Press OK to edit the value and keys to change Then press OK to confirm Press to access...

Страница 15: ...B memory to the USB port of amplifier to access this menu The USB memory must be formatted in a FAT or FAT32 file system Config Export This screen allows you to save the current configuration of the h...

Страница 16: ...K key to confirm it The PIN will be requested from the moment the Nebula comes back from sleep mode Press to access the next screen Language This screen can select the language of the display The opti...

Страница 17: ...M 35 25 dB 1 BIII DAB UHF 55 dB Regulation FM 20 dB Input BIII UHF and UHF 0 20 dB AGC Output level FM 123 dBuV BIII UHF 123 dBuV Preamplifiers feeding In all UHF inputs 0 12 24 VDC 80mA maximum per I...

Страница 18: ...dB 1 AUX 10 20 dB 1 BIII UHF 55 dB SAT 40 dB Regulation FM 20 dB AUX 20 dB BII and UHF 0 20 dB AGC SAT 20 dB Equalization SAT 0 9 2 dB Output level FM 120 dB V AUX 112 dBuV BIII DAB UHF 120 dB V SAT...

Отзывы: