Section 7
Parameter Settings
43
FT742-SM (RS422 & RS485) Sensors
– User Manual
7.4.3
AT.2: Set or Query the Acoustic Temperature Units
Command
Parameter
AT (units)
Command
Syntax
SET Sensor:
$<listenerID>,ATU<units>*<checksum><cr><lf>
$aa,ATUc*hh<cr><lf>
QUERY Sensor:
$aa,AT?U*hh<cr><lf>
Sensor output:
$<talkerID>,AT=<units>*<checksum><cr><lf>
$aa,AT=c*hh<cr><lf>
Parameters
<units>
C
The Acoustic Temperature is to be output in degrees Celsius
F
The Acoustic Temperature is to be output in degrees Fahrenheit
K
The Acoustic Temperature is to be output in Kelvin
Examples
Example 1
Set the Acoustic Temperature reading output units to degrees Fahrenheit.
Message
Comment
$01,ATUF*//<cr><lf>
Set units to Fahrenheit
$01,AT?U*//<cr><lf>
Query temperature units
$WI,AT=F*5C<cr><lf>
Sensor response
Description
Use this command to change the measurement units of the acoustic temperature output
readings. The available measurement units are degrees Celsius, Fahrenheit and Kelvin.