FSP HySpirit series User Manual
38
http://www.fsp-group.com.tw/en/product/PVInverter.html
MCU firmware version
(FW issued date)
15.
Charging Management
Charging Parameter
Default Value
Note
Charging current
60A
It is adjustable via software from
5Amp to 60Amp.
Floating charging voltage (default)
54.0 Vdc
It is adjustable via software from
50Vac to 62Vdc.
Max. absorption charging voltage
(default)
56.0 Vdc
It is adjustable via software from
50Vac to 62Vdc.
Battery overcharge protection
64.0 Vdc
Charging process based on default
setting.
3 stages:
1
st
– max. charging voltage increases
to 56V;
2
nd
- charging voltage will maintain at
56V until charging current is down to
12 Amp;
3
rd
- floating charging is at 54V.
Bulk
Floating
Absorption
time
U
time
I
Bulk Voltage
Float Voltage
This inverter can connect to following battery types: sealed lead acid battery, vented battery, gel
battery and lithium battery. The detailed installation and maintenance explanations of the
external battery pack are provided in the manual of the manufacturer’s external battery pack.
If using sealed lead acid battery, please set up the max. charging current according to the
formula below:
The maximum charging current = Battery capacity (Ah) x 0.2
For example, if you are using 300 Ah battery, then, maximum charging current is 300 x 0.2=60
(A). Please use at least 50Ah battery because the settable minimum value of charging current is
10A. If using AGM/Gel or other types of battery, please consult with installer for the details.