Insert striped cable into male terminal and crimp male terminal as shown below.
Insert assembled cable into male connector housing as shown below.
Then, use spanner to screw pressure dome tightly to female connector and male connector as
shown below.
Step 4: Check the correctness of the polarity of connection cable on PV modules and PV input
connectors. Then, connect positive pole (+) of connection cable to positive pole (+) of PV input
connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.
WARNING! For safety and efficiency, it's very important to use appropriate cables for PV module
connection. To reduce risk of injury, please use the proper cable size as recommended below.
Conductor cross-section (mm
2
)
AWG no.
4~6
10~12
CAUTION: Never directly touch the terminals of inverter. It might cause lethal electric
shock.