13
http://www.fsp-group.com.tw/en/product/PVInverter.html
L→LINE (brown or black)
→Ground (yellow-green)
N→Neutral (blue or white)
Step 3: Make sure the wires are securely connected. The
reference tightening torque is 1.4~1.6N.m.
CAUTION: It’s only allowed to connect load to “AC Output Connector”. Do NOT connect
the utility to “AC Output Connector”.
CAUTION: Be sure to connect L terminal of load to L terminal of “AC Output Connector”
and N terminal of load to N terminal of “AC Output Connector”. The G terminal of “AC
Output Connector” is connected to grounding of the load. Do NOT mis-connect.
CAUTION: This inverter is not allowed to operate in parallel. Please do NOT connect
more than one unit in parallel in AC output connector. Otherwise, it will damage this
inverter.
Diagram 4