Programming the OCS409
Programming the OCS409 is very easy and needs no specialists.
If a USB stick (e.g. included in delivery) is connected to the USB port of the OCS409, the contained con-
figuration data or software updates will be verified, loaded and programmed into the device.
During the data transfer and programming LED flashes green. After the transfer is finished, the device is
reinitialised. Therefore the first self check will be done (LED flashes yellow). Then device programs itself with
the new data. During this time the LED flashes always green. If the process is finished successful, LED stops
flashing and lights statically green.
Now you can disconnect the USB stick. During the data transfer and programming all actions are logged
to a file (LOG - file) stored on the stick.
If programming fails, LED flashes red for longer time (about 20sec.). If this signalisation time is elapsed,
LED starts to light statically green. This means that the former case was reactivated and the system works in
the last configuration.
If the LED lights statically red, you have to disconnect the device from power for a couple of seconds. The
device resets.
If there was a detected error during the configuration, this process can be redone by disconnecting and re-
connecting to the mains electricity supply (please wait about 10sec. after disconnecting).
If it is not possible to configure the device successfully after multiple tries, please look on the LOG-File
(OCS409ER.LOG) created on the flash-drive. You will find here all listed actions that have been done. This file
is readable on a PC as a normal text file.
LED-Status
Green static
Device is ready operable.
Green flashes
Device is busy, makes his initialisation, loads, stores or verifies data.
Yellow flashes
Device runs self-test. During this you can check LNB control voltages, which will
stepped through on all LNB inputs at same time.
Red flashes
Error is occurred. After about 10 sec. the last operable condition will be restored.
Red static
Device is in an error case. Reset the device by temporarily removing the power adaptor
from the wall socket. If this leads again to a static red light, please contact the support
(www.fseg.eu).