5.3 Timing Out
Time out indication alerts the operator that the product holding time has expired.
When the
holding time remaining reaches zero an audible alarm sounds and the display indicates
-00-
-00-
-00-
-00-.
All
other active displays in the cabinet will switch to the lowest intensity level until the audible alarm is
turned off.
Press the Timer key of the timed-out timer to clear the timer and turn off the audible alarm.
If
other timers in the cabinet have timed out, the audible alarm will remain on until all timers are
cleared. When all timers are cleared, active timers return to normal status.
Use First
status is
switched to the next timer with the least holding time remaining.
ENTER
PAGE
MENU
Timed Out Timer
Next Shortest Time
Inactive Timer
-00-
-00-
-00-
-00-
SAUS
SAUS
Press TIMER key to turn of audible alarm
ENTER
PAGE
MENU
SAUS
SAUS
SAUS
SAUS
SAUS
SAUS
Display returns
to inactive
Use first status changes
to the next active timer.
5.4 Buffer Timer
This feature allows an operator to adjust the holding time for a specified product by pressing the
timer key. This means product can be transferred from a remote holding cabinet and the remaining
hold time entered into another UHC. Time adjustments are in 5-minute increments.
Buffer Timer:
Pressing the timer button a
second time within three seconds allows 5-
minute decrease in holding time.
ENTER
PAGE
MENU
saus
saus
saus
saus
saus
saus
saus
saus
60
60
60
60
Initial Timer Display:
Shown when timer
is pressed after placing product in slot.
ENTER
PAGE
MENU
30
30
30
30
saus
saus
saus
saus
saus
saus
saus
saus