Automatic Filtering Fryers
4-15
Troubleshooting the AIF System (AIF)
Problem
Probable Cause
Fix
Wrong vat
opens.
1. Actuator is plugged into wrong
connector.
2. Locator pin is in wrong position.
1. Ensure the actuator is plugged into the correct
connection (J1 for FV return, J3 for DV return;
J6 for FV drain, J7 for DV drain).
2. Ensure the locator pin is in the proper position
in plug J2. (See charts on pages 1-53 — 1-60
of this manual for proper pin position.)
Actuator doesn’t
function.
1. No power to AIF board.
2. Actuator unplugged.
3. AIF board failure.
4. Actuator readings are out of
tolerance.
5. Actuator is bad.
1. Check pins 5 and 6 of J2 at the MIB board.
Should read 24VDC. Check voltage on pins
5 and 6 at the other end of the harness and
ensure 24VDC is present. Check pins 5 and 6
for 24VDC on plugs J4 and J5 on AIF boards.
2. Ensure actuator leads are plugged into AIF
board (J1 for FV return, J3 for DV return; J6
for FV drain, J7 for DV drain).
3. Check the power on the connector of the
problem actuator while manually opening
or closing the actuator. Pins 1 (black) and 4
(white) should p24VDC when the
actuator is opening; -24VDC should be read
from Pins 2 (red) and 4 (white) when the
actuator is closing. If either voltage is missing,
the AIF board is likely bad. Test the actuator
by plugging into another connector to open
or close. If the actuator operates, replace the
board.
4. Check resistance of the potentiometer
between pin 3 (purple wire) and pin 4 (gray/
white wire). Closed should read 0-560
Ω
. Open
should read 3.8K
Ω
- 6.6K
Ω
.
5. If proper voltages are seen at the connector
and the actuator doesn’t operate, replace the
actuator.
Содержание FilterQuick Series
Страница 9: ...High Efficiency Gas 2 4 H55 CM 3 5 Controller Blower Gas Valve Igniter...
Страница 11: ...High Efficiency Gas 2 6 OCF Blower Gas Valve Spark Module Igniter Gas Valve...
Страница 135: ...5 32 Touchscreen Equipped Fryers FQ4000 Information Statistics Menu Tree General Market Burger King...
Страница 136: ...5 33 Touchscreen Equipped Fryers FQ4000 Menu Tree Taco Bell...
Страница 137: ...5 34 Touchscreen Equipped Fryers FQ4000 Information Statistics Menu Tree Taco Bell...
Страница 139: ...5 36 Touchscreen Equipped Fryers FQ4000 Information Statistics Menu Tree General Market Burger King...
Страница 140: ...5 37 Touchscreen Equipped Fryers FQ4000 Menu Tree Taco Bell...
Страница 141: ...5 38 Touchscreen Equipped Fryers FQ4000 Information Statistics Menu Tree Taco Bell...
Страница 143: ...5 40 Touchscreen Equipped Fryers M4000 Information Statistics Menu Tree...
Страница 144: ...5 41 Touchscreen Equipped Fryers BIGLA30 T SERIES GEN 3 LOV GAS FRYERS M4000 Menu Summary Trees...
Страница 145: ...5 42 Touchscreen Equipped Fryers M4000 Information Statistics Menu Tree...
Страница 161: ...Charts and Tables 6 4 Reading Model Numbers 7 LQ WKLV SRVLWLRQ 7RXFKVFUHHQ...
Страница 169: ......