7-8
Problem
Probable Causes
Corrective Action
Filter pump runs,
but oil return is very
slow (contd).
B.
Attempting to filter with oil that
is not hot enough.
B.
In order to properly filter, the
oil should be at or near 350ºF
(177ºC). At temperatures
lower than this, the oil becomes
too thick to pass through the
filter medium easily, resulting
in much slower oil return and
eventual overheating of the
filter pump motor. Make sure
oil is at or near frying
temperature before draining oil
into filter pan.
M2007 display
shows
chk pan
.
A.
Filter pan is not fully set into fryer.
B.
Missing filter pan magnet.
C.
Defective filter pan switch.
A.
Pull filter pan out and fully
reinsert into fryer.
B.
Ensure the filter pan magnet is
in place and if missing replace.
C.
If the filter pan magnet is fully
against the switch and
computer continues to display
chk pan
, switch is
possibly defective.
Auto filtration won’t
start.
A.
Check that MIB board is not in
manual mode.
B.
Check to see that the MIB cover is
not damaged and depressing the
buttons.
C.
Filter relay has failed.
A.
Ensure MIB board is in “A”
automatic mode. Press the reset
button.
B.
Remove and replace cover and
see if filtration will start.
C.
Call your FASC
M2007 display
shows
filter
busy
.
Another filtration cycle is still in
process.
A.
Wait until the previous
filtration cycle ends to start
another filtration cycle.
B.
Press reset button and wait at
least 60 seconds. Computer
should clear and return to
normal operation once
complete. If the problem
continues call your FASC.