7-3
Problem
Probable Causes
Corrective Action
C.
Main power cord not plugged in.
C.
This fryer has two cords: a
120V power cord and the main
three-phase power cord. If the
120V power cord is plugged in
but the main power cord is not,
the computer will appear to
work normally, but the fryer will
not heat. Verify that both the
main power cord and 120V is
fully seated in its receptacle,
locked into place and that circuit
breaker is not tripped.
D.
One or more other components
have failed.
D.
If the circuitry in the fryer
control system cannot determine
the frypot temperature, the
system will not allow the
element to be energized or will
de-energize the element if it is
already energized. If the
contactor, element, or associated
wiring fails, the element will not
energize. Determining which
specific component is
malfunctioning is beyond the
scope of operator
troubleshooting. Call your
FASC.
Continued from
previous page.
E.
Main switch inside cabinet next to
fuse is switched to OFF.
E.
Ensure switch is switched to
ON.
Fryer does not heat
after filtering.
Drain valve is open.
This fryer is equipped with a drain
safety circuit that prevents the
heating element from being
energized if the drain valve is not
fully closed. Verify that the drain
valve is fully closed.
Fryer heats until
high-limit trips with
heat indicator ON.
Temperature probe or computer has
failed.
Call your FASC.
Fryer heats until
high-limit trips
without heat
indicator ON.
Contactor or computer has failed
Call your FASC.