4-24
4.10.4.4 Refilling the Vat from Bulk Oil Systems after Disposal
The computer displays
fill pot from bulk
(see Figure 158)
.
Figure 158
The bulk oil refill pump uses a momentary switch. It only pumps as long as the switch is depressed.
14. Press and hold the
(
1
yes
) button to refill the vat
until the oil reaches the fill line (see Figure 159).
15. With the vat full, release the
(
1
yes
) button.
Figure 159 Figure 160
16. Press the
(2)
button, when the vat is full, to close the fill valve (see Figure 160).
The computer displays
off
(see Figure 161).
Figure 161
4.11 Filter Menu
The filter menu selections are used for filtering, draining, filling and disposing.
4.11.1 Accessing the Filter Menu
Computer displays product or dashed lines (see Figure
162).
Figure 162
1. Press and hold the filter button for the selected vat for
three seconds (see Figure 163).
Figure 163
Computer displays
filter menu
for three seconds,
changing to
Auto Filter
(see Figure 164).
Figure 164
2. Press the
t
and
u
buttons (see Figure 165) to scroll
between:
a.
auto filter
See pg. 5-2
b.
maint filter
See pg. 5-8
c.
dispose
See pg. 4-19
d.
drain to pan
See pg. 4-23
e.
fill pot from DRAIN pan
See pg. 4-26
f.
fill pot from bulk
See pg. 4-28
Figure 165
Содержание Enodis BIELA14 LOV Series
Страница 18: ...4 2 4 2 Basic Operation ...
Страница 19: ...4 3 4 3 Cooking with Multi Product Display ...
Страница 20: ...4 4 4 4 Cooking with Dedicated Display ...