4-36
The vat begins to heat. The computer displays the actual vat temperature during the test. When the
temperature reaches 410°F ± 10° F (210°C ± 12°C), the high-limit should trip.
NOTE:
In
computers used in the European Union (those with the CE mark), the temperature is 395°F (202°C).
The computer displays
hot hi-1
alternating with the
actual temperature (ex.
410F
) (see Figure 268).
5. Release the
(
1
)
button. The
hi-1
test is complete.
The vat stops heating and the computer displays the
hot
hi-1
alternating with the actual temperature (ex.
410F
)
until the temperature cools below 400°F (204°C).
Figure 268
When the temperature cools below 400°F (204°C), the
display changes to
start
alternating with
hI-1
(see
Figure 269).
6. Press the
u
(
INFO
) button (see Figure 270).
Figure 269 Figure 270
The computer displays
START
alternating with
HI-2
(see Figure 271).
7. Press and hold the
(
1
yes
) button to initiate the
second high-limit test [436°F (224°C)] (see Figure
272).
Figure 271 Figure 272
The vat begins to heat. The computer displays the actual vat temperature during the test. Once the
temperature reaches 420°F to 450°F (216°C to 232°C) the second high-limit should trip. If the high-
limit fails, the computer displays
HI 2 BAD
. If this happens, turn the fryer off and call for service
immediately.
The computer displays
hi-2
alternating with the actual
temperature (ex.
430F
) (see Figure 273).
8. Release the
(
1
yes
) button.
The vat stops heating and the computer displays the
hi-
2
alternating with the actual temperature (ex.
430F
)
until the temperature cools below 400°F (204°C).
Figure 273
Once the temperature cools below 400°F (204°C) the
display changes to
start
alternating with
hI-2
(see
Figure 274).
9. Press the
(2)
button once to exit the high-limit test
(see Figure 275).
Figure 274 Figure 275