Fig.6
Various adjusters on the inside of the
welding machine
Fig.7
Fuses on the inside of the welding machine
(16)
(17)
(18)
(20)
(19)
(21)
(22)
(24)
(23)
(25)
(16) Afterglow time correction adjuster
if set correctly, prevents the welding wire from being welded to the weld pool or
contact tube
-
Manual mode ... Afterglow time can be continuously set on the scale from 0 -
0.4 sec.
-
Program mode ... allows the user to correct the afterglow time integrated into
the welding program by +/- 0.2 sec.
(17) Feeder creep speed adjuster
for adjusting a shock-free ignition when using solid and flux-core wires of min. 1.2
mm, or at high wirefeed speeds
-
Manual mode ... if in the region of 1.5 m/min, the feeder creep speed can be
adjusted up to 100% of the set wirefeed speed
-
Program mode ... for correcting the programmed feeder creep speed by
turning clockwise or anti-clockwise
(18) Interval welding time t1 or spot-welding time adjuster
has a different function depending on the mode being used
-
Interval 2-step, interval 4-step mode ... for adjusting the interval welding time
t1 (recommended operating range: 0.1 - 1.5 sec.)
-
Spot-welding ... for adjusting the spot-welding time or arc burning time for
MIG/MAG spot welding (setting range: 0.2 - 4.0 sec.)
(19) Interval pause t2
active when the operating mode selector switch is positioned at interval 2-step or
interval 4-step mode (setting range: 0.1 - 0.8 sec.
)
(20) Gas pre-flow time t1 adjuster (setting range: 0 - 3.0 sec.)
(21) Gas post-flow time t2 adjuster (setting range: 0 - 4.0 sec.)
(22) Fan fuse
(23) Fuse for feeder motor, solenoid valve, contactor
(24) Control transformer fuse
(25) Fuse for control