Specifying the charging range
It is possible to define a charging range with a min. and max. charging limit. In this case, it is not
possible for the battery to discharge.
Discharging
limit
Discharge / charge
0 W
Charging limit
Min. charging
500 W
Max. charging
3800 W
Specifying the discharging range
It is possible to define a discharging range with a min. and max. discharging limit. In this case, it
is not possible for the battery to charge.
Discharging
limit
Discharge / charge
0 W
Charging limit
Max. dischar-
ging
3000 W
Min. dischar-
ging
1000 W