1
Switch off power to the inverter and wait
for the specified time (2 minutes) until the
capacitors have discharged and the fan
has shut down.
Turn the DC disconnector to the "Off"
switch position.
2
Loosen the screws on the underside of the
housing cover by rotating them 180° to the
left using a screwdriver (TX20). Then lift
the housing cover away from the inverter
at the bottom and detach from above.
3
Remove any build-up of dirt on the heat
sink and fan using compressed air, a cloth,
or a brush.
NOTE!
Danger due to driving the fan with com-
pressed air.
Excessive speeds may be achieved. Dam-
age to the bearings may result.
▶
Clean the fan with a cloth or a brush.
To start up the inverter again, follow the steps listed above in reverse order.