Mains connec-
tion
Devices with a higher rating may affect the energy quality of the mains due to
their current consumption.
This may affect a number device types in terms of:
-
Connection restrictions
-
Criteria with regard to the maximum permissible mains impedance
*)
-
Criteria with regard to the minimum short-circuit power requirement
*)
*)
at the interface with the public grid
see "Technical data"
In this case, the plant operator or the person using the device should check
whether the device may be connected, where appropriate by discussing the mat-
ter with the power supply company.
IMPORTANT!
Ensure that the mains connection is earthed properly
Dangers from
mains current
and charging
current
Anyone working with battery chargers exposes themselves to numerous dangers,
e.g.:
-
Risk of electrocution from mains current and charging current.
-
Hazardous electromagnetic fields, which can risk the lives of those using car-
diac pacemakers.
An electric shock can be fatal. Every electric shock is potentially life threatening.
To avoid electric shocks while using the charger:
-
Do not touch any live parts inside or on the outside of the charger.
-
Under no circumstances touch the battery poles.
-
Do not short-circuit the charging cable or charging terminals.
All cables and leads must be secured, undamaged, insulated and adequately di-
mensioned. Loose connections, scorched, damaged or inadequately dimensioned
cables and leads must be immediately repaired by authorised personnel.
Dangers posed
by the battery
The substances contained in the battery to be charged can be harmful to the en-
vironment as well as to human and animal health.
If the battery becomes damaged, please observe the following points:
-
Make sure that leaking fluids cannot get into the soil or groundwater
-
If pollution has already occurred, it must be removed in accordance with rel-
evant national regulations
The battery can catch fire if overheated. Do not expose the battery to heat
(e.g. a permanent heat source or fire).
If the battery is damaged or subjected to improper use, dangerous vapours may
be given off, which can irritate the airways.
If this happens:
-
Ensure an adequate supply of fresh air
-
Seek medical attention in case of discomfort
Liquid may emerge from a faulty battery.
-
Avoid contact with the liquid
-
Take the battery to an authorised service centre for repair
-
Clean and check any parts that have come into contact with the liquid
Do not operate or store the device in a potentially explosive atmosphere.
Special regulations apply in rooms at risk of fire or explosion.
Observe relevant national and international regulations.
6
Содержание Selectiva Li 16 kW 8210
Страница 2: ......
Страница 4: ...Technical data 52 Selectiva 8 kW Li Ion 52 Selectiva 16 kW Li Ion 54 Selectiva 18 kW Li Ion 55 4...
Страница 57: ...57 EN...
Страница 58: ...58...
Страница 59: ...59 EN...
Страница 60: ......