Status codes
If a fault occurs during operation, specific status codes may be displayed. Faults
can result from the following:
-
Battery fault
-
The voltage of the connected battery is unsuitable.
-
The device has overheated.
-
There is a software or hardware fault.
Battery fault:
If the battery signals a fault, the battery charger displays this fault as a battery
fault including the corresponding fault number for the battery. The respective
fault is explained in the battery's Operating Instructions.
If an error message appears on the display and if you cannot resolve the error
yourself:
1
Note the displayed status code: e.g. "Statecode (31)".
2
Note the configuration of the device.
3
Contact your authorised service centre.
Freely-defined text, which could for example include the contact details of
the distributor, can be displayed if the device is in an error state.
Status codes caused by external factors
No.
Cause / Remedy
(11)
Check mains voltage
(12)
Check mains (phase failure)
(13)
External temperature sensor faulty
(14)
Electrolyte circulation faulty (pressure switch not switching)
(15)
Control voltage not detected
(16)
External start/stop is not closed
.
(17)
Open circuit voltage detection triggered more than once during charging
(e.g. worn charging contacts)
Status codes in the event of a battery fault
No.
Cause / Remedy
(22)
Battery undervoltage
(23)
Battery overvoltage
(24)
Battery too hot (with external temperature sensor only)
(25)
Battery too cold (with external temperature sensor only)