E16
Communication error between battery and ACCUPLT / ACCUPLT-
TIG PC board
Contact after-sales service
Cause:
Remedy:
E18
Wrong firmware (software) has been loaded
Contact after-sales service
Cause:
Remedy:
E19 / E22 / E30 / E53 / E83
Battery fault
Contact After-Sales Service
Cause:
Remedy:
E23
A voltage of > 113 V DC has been measured on the current sockets
Contact After-Sales Service
Cause:
Remedy:
No function
The power source cannot be switched on
The battery has entered a state of deep discharge as it has been
stored for too long without being charged
Charge the battery now
Battery operation is possible again above 25% capacity.
If charging is no longer possible, contact After-Sales Service.
Control panel defective
Contact After-Sales Service
Cause:
Remedy:
Cause:
Remedy:
Battery is not charged
Power source is connected to the charger, charger is connected to the mains, no
charging indicator on the power source
Device is too hot
Check/reduce ambient temperature, allow battery to cool down
Device temperature too low
Check/increase ambient temperature, disconnect and reconnect bat-
tery charger
Charging cable defective
Renew charging cable
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
63
EN
Содержание AccuPocket 150/400 TIG
Страница 2: ......
Страница 6: ...6...
Страница 7: ...Safety rules 7...
Страница 8: ...8...
Страница 24: ...24...
Страница 25: ...Power source 25...
Страница 26: ...26...
Страница 28: ...Application areas MMA welding TIG welding 28...
Страница 56: ...Every 2 months Clean the air filter if fitted 1 56...
Страница 69: ...Charger 69...
Страница 70: ...70...
Страница 84: ...84...
Страница 85: ...85 EN...
Страница 86: ...86...
Страница 87: ...87 EN...