Temperature
monitoring
Temperature monitoring prevents the battery from being charged or discharged
if the temperature of the battery is outside the permitted temperature range.
The battery charger has an internal temperature management function
-
From 30 °C: Protection against overheating of the charger by automatic re-
duction of the power (derating)
-
From 45 °C: Only standard charging possible to increase battery life
-
From 70 °C: Power source switched off
-
Charging is not possible below 0 °C. Welding is conditionally possible de-
pending on the current level.
-
Two additional sensors directly on the power module
Undertemperature
If the battery falls below the permitted temperature range, neither welding nor
charging is possible.
Overtemperature
Charging is only possible again at a battery temperature of less than +45 °C.
If the battery exceeds the permitted temperature range:
-
the temperature indicator lights up and „hot“ is shown on the display
-
neither welding nor charging is possible until the temperature indicator goes
out (when the battery has cooled down)
Overcharging
protection
Once the battery has been fully charged, the charger turns off automatically and
switches to conservation charging mode.
More information on how the battery charger and the individual operating modes
work can be found in the charger description on page
.
32
Содержание AccuPocket 150/400 TIG
Страница 2: ......
Страница 6: ...6...
Страница 7: ...Safety rules 7...
Страница 8: ...8...
Страница 24: ...24...
Страница 25: ...Power source 25...
Страница 26: ...26...
Страница 28: ...Application areas MMA welding TIG welding 28...
Страница 56: ...Every 2 months Clean the air filter if fitted 1 56...
Страница 69: ...Charger 69...
Страница 70: ...70...
Страница 84: ...84...
Страница 85: ...85 EN...
Страница 86: ...86...
Страница 87: ...87 EN...