![Froling Turbomat TM 400 Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/froling/turbomat-tm-400/turbomat-tm-400_installation-instructions-manual_2338738064.webp)
5.2 Initial startup
5.2.1 Permitted fuels
Wood chips
Criterion
ÖNORM M 7133
CEN/TS 14961
Description as per
ÖNORM M 7133
Water content
W20
M20
air-dried
W30
M30
suitable for storage
W35
-
limited suitability for
storage
W40
1)
M40
high-moisture wood
chips
W50
1)
-
freshly-harvested
wood chips
Size
G30
P16A / P16B
fine wood chip
G50
P45A
medium-sized wood
chip
G100
P63/100
coarse wood chips
2)
1.partial load conditions only to a limited extent
2.for hydraulic feeders only
NOTICE! In case of operating under partial load conditions and fuels with a water con‐
tent of >W35, power consumption of less than 65% of the nominal output is not per‐
mitted!
EU:
Fuel as per EN 14961 - Part 4: Wood chips class A2 / P16A-P63/100
Additional for
Germany:
Fuel class 4 (§3 of the First Federal Emissions Protection Ordinance
[BimSchV] - applicable version)
Wood pellets
Wood pellets made from natural wood with a diameter of 6 mm
EU:
Fuel acc. to EN 14961 - Part 2: Wood pellets class A1 / D06
and/or:
Certification program EN
plus
or DIN
plus
General note:
Before refilling the store, check for pellet dust and clean if necessary.
Wood shavings
Wood shavings generally cause problems with combustion. Therefore their use is per‐
mitted only with authorisation from Froling. The following additional points also apply:
Note on standards
Note on standards