❒ Assess the remaining fuel in the fuel-loading chamber.
Fill level
Weight at fill level
S3 Turbo 30
S3 Turbo 50
3/3
Soft wood
approx. 53 lbs (24 kg)
approx. 86 lbs (39 kg)
Hardwood
approx. 88 lbs (40 kg)
approx. 143 lbs (65 kg)
2/3
Soft wood
approx. 35 lbs (16 kg)
approx. 57 lbs (26 kg)
Hardwood
approx. 60 lbs (27 kg)
approx. 95 lbs (43 kg)
1/3
Soft wood
approx. 18 lbs (8 kg)
approx. 29 lbs (13 kg)
Hardwood
approx. 29 lbs (13 kg)
approx. 49 lbs (22 kg)
❒ Prepare the fuel quantity actually needed to load the thermal storage.
➥ The fuel quantity actually required is determined by the difference of the fuel
quantity shown on the display and the current remaining fuel in the fuel-loading
chamber.
❒ The optimal time for adding fuel is when the basic firebed is achieved.
➥ A firebed is “basic” when it reaches the top row of holes in the cladding.
❒ Open the fuel loading door, add the prepared fuel quantity, then close the fuel
loading door and insulated door again.
Display above 20 lbs
(9 kg):
5
Heating the boiler
Add more firewood during the operation
54