5.4 Heating up the boiler
❒ Open the insulated door.
➥ The induced draft fan starts running and the boiler display alternately shows
the boiler’s current values and the required fuel quantity to load the thermal
storage.
NOTICE! When calculating the fuel quantity to load into the storage tank, the energy
required for heating up the boiler (boiler water, combustion chamber) is not taken into
consideration.
❒ Prepare the fuel quantity according to what is shown on the display.
Fill level
Weight at fill level
S3 Turbo 30
S3 Turbo 50
3/3
Soft wood
approx. 53 lbs (24 kg)
approx. 86 lbs (39 kg)
Hardwood
approx. 88 lbs (40 kg)
approx. 143 lbs (65 kg)
2/3
Soft wood
approx. 35 lbs (16 kg)
approx. 57 lbs (26 kg)
Hardwood
approx. 60 lbs (27 kg)
approx. 95 lbs (43 kg)
1/3
Soft wood
approx. 18 lbs (8 kg)
approx. 29 lbs (13 kg)
Hardwood
approx. 29 lbs (13 kg)
approx. 49 lbs (22 kg)
❒ Open the fuel loading door and check the ash level
➥ Ash should remain in the boiler up to the height between the lowest and middle
rows of holes, about 3” (7 cm) of the aprons. It is recommended that you do not
remove the ash in the combustion chamber during each heating-up process,
but rather only when the middle row of holes is no longer visible, until the re‐
maining amount is about 3” (7 cm). This protects the combustion chamber and
accelerates the heating-up process.
Heating the boiler
5
Heating up the boiler
Owner´s Manual S3 Turbo | B1390016_en-us
49