5.3 Before heating up the boiler
5.3.1 Always move the WOS lever
❒ Move the lever of the cleaning system several times before the heating-up process
➥ 5-10 times up and down!
5.3.2 Reloading intervals
Reloading intervals should be determined exclusively according to the thermal storage
for efficient and environmentally-friendly heating.
5.3.3 Conversion tables and right amount of fuel
The amount of fuel added should allow the thermal storage to be heated to 100%
charge status without on/off cycling of the boiler. 100% charge status means an aver‐
age thermal storage temperature of boiler setpoint temperature (standard: 185 °F; 85
°C) minus a certain temperature which is set in the boiler controller (standard: 7 °F; 4
°C). Please note that the amount to reload also depends on the type of fuel.
100% charge status = 185 °F (85 °C) – 7 °F (4 °C) = 178 °F ( 81°C)
When the insulated door is opened the boiler display shows the required fuel quantity
to load the thermal storage to 100%. Values are shown in SI units.