❒ Slowly loosen tension of torsion spring as far as stop, remove draw tube and
tighten screw
4.3.6 Fitting adjustable feet in boiler room (optional)
If the closed duct in the boiler room exceeds 2m, an additional support is
recommended:
Ø 15 mm
❒ Remove the brackets from the supporting post
❒ Remove the screws of the trough flange at the relevant position
❒ Secure the brackets to the trough flange with the previously removed screws
❒ Position the supporting post at the bracket and screw together
Screwing the adjustable feet to the floor:
❒ Make two holes each in the floor on the left and right for the adjustable feet
❒ Drill the holes marked
- Drill diameter 15 mm
- Min. drill depth 105 mm
❒ Insert the heavy load anchors into the bore holes and tighten with a spanner (AF
17 mm)
4
Assembly
Assembling the torsion arm agitator
30