No.
Component
Int.
Operation
3
Sprinkler system
Q
Sprinkler system function test:
❒ Open ball valve only slightly
❒ Heat the sensor to above 95°C (e.g. with a lighter)
➥ The valve should open and water should flow out.
❒ Press the button on the valve briefly
➥ Water should flow out
❒ Check the opening of the sensor for dirt (dust, fuel, etc.) and clean if
necessary
4
Rotary agitator arms
F
❒ General visual inspection of the rotary agitator arms and screw joints
for damage
5
Joints with torsion springs
❒ Check that joints are correctly pre-tensioned
❒ Check torsion springs for damage
6
Mitre gear
❒ Carry out a general visual inspection
➥ No oil leaks should be visible.
7
Rotary plate
❒ Check the rotary plate for material build-up and clean if necessary
8
Trough / dosing screw
❒ Check the trough and dosing screw for dirt and damage
❒ Check the screw blades for wear
9
Inlet area / transfer channel
❒ Check the inlet area for material build-up or jammed fuel and clean if
necessary
❒ Check the shear plate in the entry area of the transfer trough for wear
10 Flange bearing
❒ Lubricate bearing at lubricating nipple with grease gun
6.2 Maintenance contract
❒ Long service life with a maintenance contract!
Regular maintenance and servicing by a qualified technician will ensure a long,
trouble-free service life for the whole system.
For this reason, FROLING offers a maintenance contract, which optimises operating
safety. Please see the details in the accompanying guarantee certificate.
Your Froling customer service office will also be happy to advise you.
6
Servicing
Maintenance contract
40