3.2 Store sizes
The articulated arm diameter and the length of the open trough vary depending on the
size of the store. The table below shows the respective dimensions:
Store length in screw direction
≤ 3.5 m ≤ 4.0 m ≤ 4.5 m ≤ 5.0 m ≤ 5.5 m ≤ 6.0 m
Articulated arm diameter (D)
[mm]
3500
4000
4500
5000
5500
6000
Open trough (L1) TGR 110/150 [mm]
1545
1795
2045
2295
2545
2795
Open trough (L1) TGR 200 [mm]
1530
1780
2030
2280
2530
2785
A
❒ The nominal diameter of the discharge must be selected according to the lateral
length (A) of the space that runs parallel to the feed screw.
❒ The discharge must be positioned so that the shear edge (transition from open to
closed trough) is at least 200 mm away from the wall.
3.3 Technical specifications
Description
T4 24-75 T4 90-110
TM 150
TX 150
TM 220-320
TX 199-250
TM 400-500
Screw diameter
110 mm
150 mm
200 mm
Drive motor –
Feed screw
Power
supply
400 VAC / 50 Hz
Power
0.37 kW
0.55 kW
0.37 kW
0.75 kW
1.1 kW
Gear output speed
4.5 rpm
10.5 rpm
4.5 rpm
10.5 rpm
10.5 rpm
Safety switch
24 VDC
Description
T4 24-75
T4 90-110
TM 150-320
TX 150-250
TM 400-500
Screw diameter
110 mm
150 mm
Drive motor –
Feed screw
Power
supply
400 VAC / 50 Hz
Power
0.37 kW
0.55 kW
0.37 kW
0.75 kW
Gear output speed
4.5 rpm
10.5 rpm
4.5 rpm
10.5 rpm
Safety switch
24 VDC
Operation with wood
chips
Operation with pellets
3
Technology
Store sizes
16