Installation Tips to Ensure Proper Performance
1) If using a multi-speed pump, run
pump for at least 6 hours per day at
high speed (at least 40 gpm).
If the pump will run on low speed 24
hours per day or less than 6 hours per
day on high speed, you must bleed the
air while the pump is on by unscrewing
the back knob until water appears.
Then screw the knob back in. Repeat
this process each time the cap is
removed for any reason.
2) Install system with 4-8 psi back pressure.
Lower back pressures could result in under
chlorination. Change the eyeball fittings in
the return jets to a smaller size to increase
back pressure. Contact King Technology at
800-222-0169 for a specially designed
Infuzer pressure gauge to determine back
pressure at pool start-up.
3) Special installation Requirements:
A. With High Flow Rate
(greater than 80 gpm)
Install T-fittings exactly as shown.
B. With In-Floor Cleaner - TWO OPTIONS
The best option is to have two lines.
One line with pump, filter, heater and
FROG Leap Infuzer and a second line with a separate pump for the in-floor
cleaning system (filter optional).
OPTION 1- A Two-Line Installation
POOL RETURN
FROG Leap Infuzer
FROG Leap Infuzer
FROG Leap Infuzer
FROG Leap Infuzer
IN-FLOOR
CLEANER
VALVE
FILTER
FILTER
HEATER
OPTION 2 - A 3-Way Valve Installation
POOL WATER LEVEL
3-way manual valve or 3-way motor valve plus controls
IN-FLOOR
CLEANER
VALVE
FILTER
PUMP
PUMP
PUMP
C. Pool and Spillover Spa Combination
Line 1
Line 2
POOL WATER LEVEL
POOL WATER LEVEL
WARNING
• Do not exceed maximum operating pressure of 50 psi.
• Do not install automatic or fast shut off valves
downstream of feeder.
• Always install the FROG Leap Infuzer AFTER the
heater (if applicable) on the return line.
• Always install any additional sanitizing equipment
AFTER and NEVER BEFORE the FROG Leap Infuzer is
installed on the return line.
•
If water flow is higher than 80 gallons per minute (gpm),
see diagram A.
•
If an in-floor cleaner is included with pool,
see diagram B, with two options. Preferred
installation is Option 1 with two separate lines.
•
If set-up is a pool and spa combination with
common equipment, see diagram C.
Questions?
Call Customer Service at 800-222-0169
Monday thru Friday, 8 am to 5 pm central time.
IMPORTANT:
Over chlorination or damage to the FROG
Leap Infuzer or other equipment could result if special
installations A, B or C are not used in these situations.
Before installing, read all directions carefully and contact your dealer for installation support.