Fire, explosion and high pressure hazards

To minimize the risk of serious injury, death or property damage while using the FROG Leap Infuzer:

Read, understand and follow all instructions and safety precautions in the manual, and on this Infuzer and on any label for chemicals used

           with this Infuzer including FROG Leap Torpedo Pacs, FROG Leap Anti-Bac Mineral Pacs and FROG Leap Pool Wake Up!/Pool Hibernation 
          (which includes FROG Leap Reveille, FROG Leap Depth Charge and FROG Leap All-Out).

    DANGER

Never use fast dissolving chlorine tablets, liquid bleach, or calcium hypochlorite in the FROG Leap Infuzer.

Never mix Trichlor chlorine tablets with Calcium Hypochlorite, or with any other form of concentrated chlorine or other chemicals.

Never add any other types of chlorine, pH adjusters, shock treatments or algaecides through the skimmer.  

          These products should be added directly into the pool if required.

Do not contaminate the FROG Leap Infuzer, FROG Leap Anti-Bac Mineral Pac, FROG Leap Torpedo Pac and FROG Leap Pool Wake Up!/Pool Hibernation

            (which includes FROG Leap Reveille, FROG Leap Depth Charge and FROG Leap All-Out) with dirt, organic matter, pool chemicals (such as calcium 
            hypochlorite or pool shocks), fertilizers or other household chemicals. Contact between any of these substances and the FROG Leap Infuzer including
            FROG Leap Anti-Bac Mineral Pac, FROG Leap Torpedo Pac, FROG Leap Pool Wake Up!/Pool Hibernation (which includes FROG Leap Reveille, FROG
            Leap Depth Charge and FROG Leap All-Out) will result in a chemical reaction with the generation of heat, liberation of hazardous gasses and 
          fire or explosion.

     

WARNING

Use only FROG Leap Torpedo Pacs, FROG Leap Anti-Bac Mineral Pacs, FROG Leap Pool Wake Up!/Pool Hibernation (which includes FROG Leap

           Reveille, FROG Leap Depth Charge and FROG Leap All-Out) in the FROG Leap Infuzer. Never use bulk chemicals. 

To prevent the build up of gas pressure in the FROG Leap Infuzer, be sure the pool return line valves are open –

           except when opening or servicing the unit.

Do not inhale fumes from the FROG Leap Infuzer or FROG Leap Torpedo Pac.

Avoid sparks, smoking, or any open flame near FROG Leap Infuzer or chemicals.

Do not exceed maximum operating pressure of 50 psi or maximum temperature of 104º F.

Do not remove the cap while under pressure. Always turn off pump and bleed off pressure before opening FROG Leap Infuzer.

Do not install automatic or fast shut off valves downstream of Infuzer.

Always install the FROG Leap Infuzer AFTER a heater (if applicable) on the return line.

Always install any additional sanitizing equipment AFTER and NEVER BEFORE the FROG Leap Infuzer is installed on the return line.

Do not permit children to use or climb on this product. This product must be positioned to prevent children from using it as a

  

means of access to the pool.

Always stand clear of the FROG Leap Infuzer during pump start-up.

Replace FROG Leap Infuzer if you see signs of cracks, damage or degradation to the Infuzer body or cap.

NOTICE

NOTICE

Prior to pressurizing, check with your dealer to ensure your plumbing connections meet building codes.

Failure to properly winterize your FROG Leap Infuzer could result in freeze damage. (See page 19 for winterizing details.)

Review this label before installing or operating this Infuzer. Contact King Technology at 800-222-0169 if this label is missing from your FROG Leap Infuzer.

Safety Label on Infuzer  

Содержание Leap 7800

Страница 1: ...Clearer because it helps keep pH in range Softer because it reduces chlorine use up to 50 Easier with prefilled pacs for no mess no guess and no stress To minimize the risk of serious injury death or...

Страница 2: ...0 11 Step 2 Putting the System to Work 12 Step 3 Setting the Control Dial 13 Step 4 Routine Pool Care 14 Replacing FROG Leap Anti Bac Mineral Pac 15 Using FROG Leap Pool Wake Up 16 Using FROG Leap All...

Страница 3: ...Anti Bac Mineral Pac Part No 01 03 7937 FROG Leap Anti Bac Mineral Pac comes inside the FROG Leap Infuzer and is also sold separately Also sold separately FROG Leap Torpedo Pac FROG Leap All Out Part...

Страница 4: ...ctographs illustrate the type of hazard Pictograph Type of Danger Safety Alert General Hazard Explosion Risk Hazardous Pressure Flammable Fire Hazard Identification of warnings Warnings are intended t...

Страница 5: ...OG Leap Torpedo Pacs FROG Leap Anti Bac Mineral Pacs FROG Leap Pool Wake Up Pool Hibernation which includes FROG Leap Reveille FROG Leap Depth Charge and FROG Leap All Out in the FROG Leap Infuzer Nev...

Страница 6: ...OOL RETURN FROG Leap Infuzer FROG Leap Infuzer FROG Leap Infuzer FROG Leap Infuzer IN FLOOR CLEANER VALVE FILTER FILTER HEATER OPTION 2 A 3 Way Valve Installation POOL WATER LEVEL 3 way manual valve o...

Страница 7: ...ipe thread tape or sealant to each threaded end of nipple 1 Screw either side of FROG Leap Infuzer on to open nipple end until upright and secure Apply pipe thread tape or sealant to threaded end of h...

Страница 8: ...tions with pipe wrench DO NOT OVER TIGHTEN 2 Attach the filter section of flex hose to one hose adapter and the return section of flex hose to the other hose adapter with clamps and tighten with screw...

Страница 9: ...b 3 Pipe Wrench Bi flow valve design allows installation in either flow direction Pipe Thread Tape or Sealant Primer and PVC Cement If using male adapters apply pipe thread tape or sealant to the thre...

Страница 10: ...e adding to the pool If calcium content is higher than 400 ppm find a soft water source to fill your pool instead otherwise water balance will be very difficult Check for metals in the pool such as ir...

Страница 11: ...low 80 ppm Important Keep cap on tight between uses Store at room temperature www KingTechnology com Patent 6 030 842 Made in USA 553101443N Read v w IDEAL USE BY DATE ON BOTTLE USE ANTES FECHA SmartC...

Страница 12: ...ap Anti Bac Mineral Pac in the Infuzer See page 17 for directions Use FROG Leap All Out for a 90 day Algae Protection Guarantee When chlorine reading is down to 1 0 ppm which may take a few days inser...

Страница 13: ...RECOMMENDED FLOW RATE 20 60 gpm NR This pump size is not recommended for this size pool 24 HOUR LOW SPEED PUMP RUN TIME In order to ensure proper performance when running the pump on low speed for 24...

Страница 14: ...maintaining water balance regularly is important WARNING TopreventthebuildupofgaspressureintheFROGLeap Infuzer besurethepoolreturnlinevalvesareopenexcept whenopeningorservicingtheunit DANGER Never ad...

Страница 15: ...h fin inside the FROG Leap Infuzer Lower FROG Leap Anti Bac Mineral Pac into FROG Leap Infuzer until secure Replace the FROG Leap Torpedo Pac inside the FROG Leap Anti Bac Mineral Pac to continue oper...

Страница 16: ...p 1 2 3 4 FROG Leap Depth Charge FROG Leap Reveille Run the pump and filter for each pac according to the directions on the product label Remove from the FROG Leap Infuzer when empty and discard in tr...

Страница 17: ...in FROG Leap Infuzer to puncture seal Replace cap by hand only DO NOT OVER TIGHTEN Turn control dial on FROG Leap Infuzer to Setting 10 2 3 4 5 Turn pump on for 90 minutes allowing FROG Leap All Out...

Страница 18: ...ROG Leap Torpedo Pac is required to assure up to 50 reduction in chlorine use FROG Leap Torpedo Pac sold separately EPA Reg No 53735 2 2 3 4 5 6 7 Replace cap by hand only DO NOT OVER TIGHTEN The chlo...

Страница 19: ...in If FROG Leap Torpedo Pac still contains chlorine wrap in plastic bag and store in shed or cool dry well ventilated location away from children pets cars motorcycles or anything metal that can rust...

Страница 20: ...r if not bleed the air from the back knob each time cap is open 5 Contact your dealer to have your back pressure tested If under 4 psi consider a smaller eyeball fitting in the return jet 6 Check for...

Страница 21: ...ipple Kit 1 Replacement parts for FROG Leap Infuzer 7800 REF PART NO DESCRIPTION 1 2 01 22 1426 Cap w O Ring 2 01 22 1922 Cap O Ring 4 01 22 9485 Pressure Relief Valve 5 6 7 8 01 22 1457 Control Dial...

Страница 22: ...al until it locks into place Lubricate O ring every couple of months with silicone lubricant that came with your FROG Leap Infuzer DO NOT USE petroleum based lubricants 1 1 2 2 3 4 5 5 SILICONE LUBRIC...

Страница 23: ...f the chemicals used in the product or their characteristics 3 Any express warranty not provided for herein and any remedy for breach of warranty or breach of contract which but for this provision mig...

Страница 24: ...g Technology Inc FROG FROG Leap Torpedo Pac FROG Leap FROG Leap Pool Wake Up Pool Hibernation FROG Leap Anti Bac Mineral Pac Fresh Mineral Water 530 11TH AVE S HOPKINS MN 55343 800 222 0169 frogproduc...